SLTS262K October 2005 – May 2026 PTH08T210W
PRODUCTION DATA
The TurboTrans resistor value, RTT can be determined from the TurboTrans programming equation, see Equation 1.
Where CO is the total output capacitance in μF. CO values greater than or equal to 2350 μF require RTT to be a short, 0Ω. (Equation 1 will result in a negative value for RTT when CO ≥ 2350 μF.)

| 1000 ≤ C(μF)xESR(mΩ) ≤ 5000 | 12-V Input |

| 1000 ≤ C(μF)xESR(mΩ) ≤ 5000 | 12-V Input |
| Transient Voltage Deviation (mV) | 12 V Input | 8 V Input | ||||
|---|---|---|---|---|---|---|
| 25% Load Step (7.5 A) |
50% Load Step (15 A) |
75% Load Step (22.5 A) |
CO Minimum Required Output Capacitance (μF) |
RTT Required TurboTrans Resistor (Ω) |
CO Minimum Required Output Capacitance (μF) |
RTT Required TurboTrans Resistor (Ω) |
| 100 | 200 | 300 | 470 | open | 540 | 205 k |
| 90 | 180 | 270 | 500 | 499 k | 620 | 93.1 k |
| 80 | 160 | 240 | 580 | 127 k | 720 | 52.3 k |
| 70 | 140 | 210 | 680 | 63.4 k | 840 | 32.4 k |
| 60 | 120 | 180 | 800 | 37.4 k | 1000 | 20.5 k |
| 50 | 100 | 150 | 1000 | 20.5 k | 1300 | 10.2 k |
| 40 | 80 | 120 | 1300 | 10.2 k | 1700 | 4.22 k |
| 30 | 60 | 90 | 1800 | 3.32 k | 2300 | 221 |
| 25 | 50 | 75 | 2200 | 698 | 4900 | 0 |
| 20 | 40 | 60 | 5400 | 0 | 14000 | 0 |