Figure 5-10 Ambient Temperature vs. Output Current
Figure 5-7 Output Ripple vs. Output Current
Figure 5-9 Ambient Temperature vs. Output Current
3. The electrical characteristic data has been developed from actual products tested at 25°C. This data is considered typical for the converter. Applies to Figure 5-6, Figure 5-7, and Figure 5-8.
4. The temperature derating curves represent the conditions at which internal components are at or below the manufacturer's maximum operating temperatures. Derating limits apply to modules soldered directly to a 100 mm × 100 mm double-sided PCB with 2 oz. copper. Applies to Figure 5-9 and Figure 5-10.