over operating free-air temperature range (unless otherwise noted)(1) | MIN | MAX | UNIT |
|---|
| Electrical fast transient | IEC 61000-4-5 (5/50 ns) | | 80 | A |
| Peak pulse | IEC 61000-4-5 power (tp - 8/20 µs) | | 15 | W |
| IEC 61000-4-5 current (tp - 8/20 µs) | | 1.7 | A |
| TA | Operating free-air temperature | –40 | 125 | °C |
| Tstg | Storage temperature | –65 | 155 | °C |
(1) Operation outside the Absolute Maximum Ratings may cause permanent device
damage. Absolute Maximum Ratings do not
imply functional operation of the device at these
or any other conditions beyond those listed under
Recommended Operating Conditions. If used
outside the Recommended Operating
Conditions but within the Absolute Maximum
Ratings, the device may not be fully
functional, and this may affect device
reliability, functionality, performance, and
shorten the device lifetime.