SLVSHP9 July 2026 TPS544A28
PRODUCTION DATA
The device implements a selectable (0.5ms, 1ms, 2ms, or 4ms) soft-start time which can be configured via pinstrap or the digital interface. The soft-start time can be set digitally through (61h) TON_RISE as outlined in Table 7-10. The device also implements a soft-stop time mirroring the soft-start time that can be enabled/disabled in (01h) OPERATION. If soft-stop is not enabled, then the device responds as defined in Section 7.3.17 on disable.
| TON_RISE [3:0] | SOFT-START TIME (ms) | |
|---|---|---|
| ≥ | ≤ | |
| 0d | 1d | 0.5 |
| 2d | 3d | 1 |
| 4d | 7d | 2 |
| 8d | 15d | 4 |
The device includes optional (60h) TON_DELAY between enable and start of switching and (64h) TOFF_DELAY between disable and start of voltage ramp down. The timing is outlined in Soft-Start and Soft-Stop Timing.
Figure 7-7 Soft-Start and Soft-Stop Timing