SLVSI26 July 2026 TPS1HC03-Q1
PRODMIX
Set the adjustable current limit of the device using Equation 13 for valid range of RLIM resistor mentioned in Table 8-1.
The accuracy of current limit depends on RLIM resistor tolerance and KCL parameter variation (KCL_min, KCL_max) mentioned in Electrical Characteristics. Considering RLIM resistor with 1% tolerance, the below equations show ICL minimum and maximum value calculation.
For RLIM GND and OPEN case, KCL parameter variation contributes to ICL variation.