SLVSIZ2 April 2026 FAN31790
PRODUCTION DATA
When enabled, the FAN31790 continuously monitors tachometer signals to detect when a fan has stopped spinning or is running abnormally. The device can detect fan failures in three distinct ways depending on the control mode (PWM mode, RPM mode, or locked rotor mode). Once a fault condition is detected, it is counted in a fault queue and the host can configure whether 1, 2, 4, or 6 consecutive fault detections are required before the fan is declared failed. After the selected number of consecutive faults occur, the FAN_FAIL output asserts (unless masked) and the fault bit is set in the Fan Fault Status registers (10h, 11h). The failed condition persists until the host clears it by writing a new value to either the PWM Target Duty Cycle or TACH Target Count register for that fan.