SLVSLM8 May 2026 BQ78709-Q1
PRODUCTION DATA
The BQ78709-Q1 device integrates a voltage ADC which is multiplexed between measurements of cell voltages, an internal temperature sensor, the TS pin, and also performs measurements of the voltage at the VC7 pin, the internal 1.8V LDO voltage, and the VSS rail (for diagnostic purposes). The BQ78709-Q1 device supports measurement of individual differential cell voltages in a series configuration, ranging from 2-series cells to 7-series cells. Each cell voltage measurement is a differential measurement of the voltage between two adjacent cell input pins, such as VC1-VC0, VC2-VC1, and so forth. The cell voltage measurements are processed based on trim corrections and then reported in 16-bit resolution using units of 1mV. The cell voltage measurements can support a recommended voltage range from -0.2V to 5.5V. The voltage ADC saturates at a level of 5 × VREF1 (approximately 6.06V) when measuring cell voltages, although for best performance it is recommended to stay at a maximum input of 5.5V.