SLVSMQ4 September 2026 TPS7H5101-SEP
ADVANCE INFORMATION
The TPS7H5101 has a simple PMBus interface designed to allow margining the output voltage +10% to -10% and enabling and disabling the device. Additionally, PEC (packet error checking) is included along with fault handling to aid in robust communication.
This PMBus interface supports the following command protocols: Send Byte, Write Byte, and Read Byte. Each of the protocols has a standard version and PEC version to allow for flexibility.
All PMBus transactions utilize the START and STOP commands to frame the data packet and the REPEAT START condition is allowed when necessary. The device can operate in standard mode (100kb/s). The TPS7H5101 device does not stretch pulses on the PMBus when communicating with the controller.
The PMBus is active and ready for transactions a period of 5ms after the input voltage VIN of the TPS7H5101 is above the VINUVLO threshold of the controller. Sending transactions before this initialization period is completed is not advised as any PMBus actions are potentially perceived as invalid. All registers are reset to default values during initialization. Note that the "ON_OFF" bit of the OPERATION register defaults to the "on" state after the PMBus initialization, regardless of the state of the external enable pin for the controller.