SPRUHM9H October 2014 – May 2024 TMS320F28075 , TMS320F28075-Q1 , TMS320F28076
Based on a given analog input voltage, the expected digital conversion is given in Table 10-2. Fractional values are truncated.
| Analog Input | Digital Result |
|---|---|
| when ADCINy ≤ VREFLO | ADCRESULTx = 0 |
| when VREFLO < ADCINy < VREFHI | ADCRESULTx = 4096
![]() |
| when ADCINy ≥ VREFHI | ADCRESULTx = 4095 |