APU data memory write operation fails.
Revisions Affected
FDescription
APU Data memory write operation fails if two write operations occur back-to-back.Workaround
Customers must always use the TI APU driver to access APU data memory. This workaround is incorporated into the SimpleLink™ Low Power F3 software development kit (SDK) version 9.11 and newer.