TIDT435 February   2025

 

  1.   1
  2.   Description
  3.   Features
  4.   Applications
  5. 1Test Prerequisites
    1. 1.1 Voltage and Current Requirements
    2. 1.2 Required Equipment
    3. 1.3 Considerations
    4. 1.4 Dimensions
  6. 2Testing and Results
    1. 2.1 Efficiency Graphs
    2. 2.2 Efficiency Data
    3. 2.3 Thermal Images
    4. 2.4 Bode Plots
    5. 2.5 Light Load Efficiency Optimization
    6. 2.6 Midpoint Voltage Balance Control of Input Capacitors
  7. 3Waveforms
    1. 3.1 Switching
    2. 3.2 Output Voltage Ripple
    3. 3.3 Turn ON and OFF
    4. 3.4 Load Transients
  8.   Trademarks

Switching

Switching behavior of Secondary MOSFET is shown in Figure 3-1 through Figure 3-24. The test condition is room temperature.

CH1: Vgs of Secondary MOSFET

CH2: Vds of Secondary MOSFET

CH3: Differential voltage of transformer primary winding

CH4: Current waveform of transformer primary winding

PMP41139 Switching at 400Vin,
                            9Vout, 20A LoadFigure 3-1 Switching at 400Vin, 9Vout, 20A Load
PMP41139 Switching at 400Vin,
                            9Vout, 120A LoadFigure 3-3 Switching at 400Vin, 9Vout, 120A Load
PMP41139 Switching at 400Vin,
                            13.5Vout, 60A LoadFigure 3-5 Switching at 400Vin, 13.5Vout, 60A Load
PMP41139 Switching at 600Vin,
                            9Vout, 20A LoadFigure 3-7 Switching at 600Vin, 9Vout, 20A Load
PMP41139 Switching at 600Vin,
                            9Vout, 250A LoadFigure 3-9 Switching at 600Vin, 9Vout, 250A Load
PMP41139 Switching at 600Vin,
                            13.5Vout, 120A LoadFigure 3-11 Switching at 600Vin, 13.5Vout, 120A Load
PMP41139 Switching at 600Vin,
                            16Vout, 20A LoadFigure 3-13 Switching at 600Vin, 16Vout, 20A Load
PMP41139 Switching at 600Vin,
                            16Vout, 250A LoadFigure 3-15 Switching at 600Vin, 16Vout, 250A Load
PMP41139 Switching at 800Vin,
                            9Vout, 120A LoadFigure 3-17 Switching at 800Vin, 9Vout, 120A Load
PMP41139 Switching at 800Vin,
                            13.5Vout, 20A LoadFigure 3-19 Switching at 800Vin, 13.5Vout, 20A Load
PMP41139 Switching at 800Vin,
                            13.5Vout, 250A LoadFigure 3-21 Switching at 800Vin, 13.5Vout, 250A Load
PMP41139 Switching at 800Vin,
                            16Vout, 120A LoadFigure 3-23 Switching at 800Vin, 16Vout, 120A Load
PMP41139 Switching at 400Vin,
                            9Vout, 60A LoadFigure 3-2 Switching at 400Vin, 9Vout, 60A Load
PMP41139 Switching at 400Vin,
                            13.5Vout, 20A LoadFigure 3-4 Switching at 400Vin, 13.5Vout, 20A Load
PMP41139 Switching at 400Vin,
                            13.5Vout, 120A LoadFigure 3-6 Switching at 400Vin, 13.5Vout, 120A Load
PMP41139 Switching at 600Vin,
                            9Vout, 120A LoadFigure 3-8 Switching at 600Vin, 9Vout, 120A Load
PMP41139 Switching at 600Vin,
                            13.5Vout, 20A LoadFigure 3-10 Switching at 600Vin, 13.5Vout, 20A Load
PMP41139 Switching at 600Vin,
                            13.5Vout, 250A LoadFigure 3-12 Switching at 600Vin, 13.5Vout, 250A Load
PMP41139 Switching at 600Vin,
                            16Vout, 120A LoadFigure 3-14 Switching at 600Vin, 16Vout, 120A Load
PMP41139 Switching at 800Vin,
                            9Vout, 20A LoadFigure 3-16 Switching at 800Vin, 9Vout, 20A Load
PMP41139 Switching at 800Vin,
                            9Vout, 250A LoadFigure 3-18 Switching at 800Vin, 9Vout, 250A Load
PMP41139 Switching at 800Vin,
                            13.5Vout, 120A LoadFigure 3-20 Switching at 800Vin, 13.5Vout, 120A Load
PMP41139 Switching at 800Vin,
                            16Vout, 20A LoadFigure 3-22 Switching at 800Vin, 16Vout, 20A Load
PMP41139 Switching at 800Vin,
                            16Vout, 250A LoadFigure 3-24 Switching at 800Vin, 16Vout, 250A Load