Number of receivers 1 Number of transmitters 1 Duplex Full, Half Logic voltage (min) (V) 1.65 Signaling rate (max) (Mbps) 20 IEC 61000-4-2 contact (±V) 8000 Fault protection (V) -16 to 16 Common-mode range (V) -7 to 12 Number of nodes 256 Features 1.65-V I/O supply, IEC ESD protection, PROFIBUS, Switchable termination resistor Isolated No Supply current (max) (µA) 3000 Rating Catalog Operating temperature range (°C) -40 to 125
Number of receivers 1 Number of transmitters 1 Duplex Full, Half Logic voltage (min) (V) 1.65 Signaling rate (max) (Mbps) 20 IEC 61000-4-2 contact (±V) 8000 Fault protection (V) -16 to 16 Common-mode range (V) -7 to 12 Number of nodes 256 Features 1.65-V I/O supply, IEC ESD protection, PROFIBUS, Switchable termination resistor Isolated No Supply current (max) (µA) 3000 Rating Catalog Operating temperature range (°C) -40 to 125
VQFN (RGT) 16 9 mm² (3 mm × 3 mm)
  • Meets or exceeds the requirements of the TIA/EIA-485A standard
  • 3-V to 5.5-V bus supply voltage
  • 1.65 V to 5.5 V supply for logic signals
  • Differential output exceeds 2.1 V for PROFIBUS compatibility with 5-V supply
  • Pin configurable Half-duplex and full-duplex
  • Pin controlled on-chip 120 Ω termination resistor on bus pins
  • Maximum Data rate configurable
    • SLR = High: 500 kbps
    • SLR = Low or floating: 20 Mbps
  • Bus I/O protection
    • ±16-kV HBM ESD
    • ±8-kV IEC 61000-4-2 Contact discharge
    • ±15-kV IEC 61000-4-2 Air gap discharge
    • ±4-kV IEC 61000-4-4 Fast transient burst
    • ±16-V bus fault protection (absolute max voltage on bus pins)
  • Extended industrial temperature range: -40°C to 125°C
  • Low power consumption
    • Shutdown supply current < 5 µA
    • Quiescent current during operation < 3 mA
  • Glitch-free power-up/power-down for hot plug-in capability
  • Open, short, and idle bus failsafe
  • Small, space-saving 16-VQFN (3 mm x 3 mm) package
  • Meets or exceeds the requirements of the TIA/EIA-485A standard
  • 3-V to 5.5-V bus supply voltage
  • 1.65 V to 5.5 V supply for logic signals
  • Differential output exceeds 2.1 V for PROFIBUS compatibility with 5-V supply
  • Pin configurable Half-duplex and full-duplex
  • Pin controlled on-chip 120 Ω termination resistor on bus pins
  • Maximum Data rate configurable
    • SLR = High: 500 kbps
    • SLR = Low or floating: 20 Mbps
  • Bus I/O protection
    • ±16-kV HBM ESD
    • ±8-kV IEC 61000-4-2 Contact discharge
    • ±15-kV IEC 61000-4-2 Air gap discharge
    • ±4-kV IEC 61000-4-4 Fast transient burst
    • ±16-V bus fault protection (absolute max voltage on bus pins)
  • Extended industrial temperature range: -40°C to 125°C
  • Low power consumption
    • Shutdown supply current < 5 µA
    • Quiescent current during operation < 3 mA
  • Glitch-free power-up/power-down for hot plug-in capability
  • Open, short, and idle bus failsafe
  • Small, space-saving 16-VQFN (3 mm x 3 mm) package

The THVD1424 is a flexible RS-485 transceiver for industrial applications. The device has features such as on-chip 120-Ω termination resistor, slew rate control and interchangeability between half and full duplex mode. All the features are pin-controlled. This enables the device to be used at any node location (end nodes or middle nodes) in any network, two-wire (half duplex) or 4-wire (full duplex), slow or fast. End-equipment designers can now design a common printed circuit board (PCB) and configure it via software for various application needs. This can save considerable design and qualification time for the customers.

The bus pins are immune to high levels of IEC Contact Discharge ESD events, eliminating the need for additional system level protection components. The device operates from 3 to 5.5-V bus supply, while the logic supply voltage range is 1.65 V to 5.5 V. The wide common-mode voltage range and low input leakage on bus pins makes the devices suitable for multi-point applications over long cable runs.

The device is available in a space-saving, thermally efficient 16-pin VQFN package. The device is characterized for ambient temperatures from –40°C to 125°C.

The THVD1424 is a flexible RS-485 transceiver for industrial applications. The device has features such as on-chip 120-Ω termination resistor, slew rate control and interchangeability between half and full duplex mode. All the features are pin-controlled. This enables the device to be used at any node location (end nodes or middle nodes) in any network, two-wire (half duplex) or 4-wire (full duplex), slow or fast. End-equipment designers can now design a common printed circuit board (PCB) and configure it via software for various application needs. This can save considerable design and qualification time for the customers.

The bus pins are immune to high levels of IEC Contact Discharge ESD events, eliminating the need for additional system level protection components. The device operates from 3 to 5.5-V bus supply, while the logic supply voltage range is 1.65 V to 5.5 V. The wide common-mode voltage range and low input leakage on bus pins makes the devices suitable for multi-point applications over long cable runs.

The device is available in a space-saving, thermally efficient 16-pin VQFN package. The device is characterized for ambient temperatures from –40°C to 125°C.

Descargar Ver vídeo con transcripción Video

Productos similares que pueden interesarle

open-in-new Comparar alternativas
Misma funcionalidad con diferente configuración de pines que el dispositivo comparado
THVD1454 ACTIVO Transceptor RS-485 semidúplex de 3 V a 5.5 V con terminación integrada conmutable de 120 Ω. Supports half duplex configuration

Documentación técnica

No se encontraron resultados. Borre su búsqueda y vuelva a intentarlo.
Ver todo 5
Documentación principal Tipo Título Opciones de formato Descargar la versión más reciente en inglés Fecha
* Hoja de datos THVD1424 3-V to 5.5-V RS-485 Transceiver With Slew Rate Control, Integrated120-Ohm Switchable Termination Resistor and Duplex Switching datasheet (Rev. A) PDF | HTML 28/03/2023
Nota sobre la aplicación Flexible RS-485: A Simplified Multi-System Design for RS-485 Using the THVD1424 PDF | HTML 13/09/2023
Informe Reduce System Design Time and Cost with Flexible RS-485 Transceivers (Rev. C) PDF | HTML 1/06/2023
Certificado THVD1424EVM EU RoHS Declaration of Conformity (DoC) 20/09/2022
Artículo técnico Frequently asked questions and answers for RS-485 transceivers PDF | HTML 9/04/2019

Diseño y desarrollo

Para conocer los términos adicionales o los recursos necesarios, haga clic en cualquier título de abajo para ver la página de detalles cuando esté disponible.

Placa de evaluación

THVD1424EVM — Módulo de evaluación THVD1424 para terminación conmutable integrada RS-485 y conmutación dúplex

El THVD1424EVM proporciona una forma rápida de evaluar nuestro THVD1424, un transceptor RS-485 dúplex completo con tasa de datos seleccionable y resistencias de terminación integradas conmutables, en el encapsulado 16-VQFN (RJT).

Guía del usuario: PDF | HTML
Productos y hardware compatibles
En inventario
Límite:
??asset.out-of-stock-ti_es_MX??
No disponible
Encapsulado Pines Símbolos CAD, huellas y modelos 3D
VQFN (RGT) 16 Ultra Librarian

Pedidos y calidad

Los productos recomendados pueden tener parámetros, módulos de evaluación o diseños de referencia relacionados con este producto de TI.

Soporte y capacitación

Foros de TI E2E™ con asistencia técnica de los ingenieros de TI

El contenido lo proporcionan “tal como está” TI y los colaboradores de la comunidad y no constituye especificaciones de TI. Consulte los términos de uso.

Si tiene alguna pregunta sobre calidad, encapsulados o pedido de productos de TI, consulte el servicio de asistencia de TI. ​​​​​​​​​​​​​​

Videos