JAJU802A January 2022 – October 2022
Objectives learned in this build level:
This system is running with open-loop control, the ADC measured values are only used for instrumentation purposes in this build level. The high voltage DC power supply is implemented on the inverter, the bias power supply for MCU controller and gate drivers is provided by the auxiliary power supply module. The software flow for this build level is shown in Figure 3-15.