Fault Status-2 is shown in Figure 7-30 and described in Table 7-21.
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| OLD4 | OLD3 | OLD2 | OLD1 | OCP4 | OCP3 | OCP2 | OCP1 |
| R-0b | R-0b | R-0b | R-0b | R-0b | R-0b | R-0b | R-0b |
| Bit | Field | Type | Reset | Description |
|---|---|---|---|---|
| 7 | OLD4 | R | 0b | 0b = No open load detected on OUT4 1b = Open load detected on OUT4 |
| 6 | OLD3 | R | 0b | 0b = No open load detected on OUT3 1b = Open load detected on OUT3 |
| 5 | OLD2 | R | 0b | 0b = No open load detected on OUT2 1b = Open load detected on OUT2 |
| 4 | OLD1 | R | 0b | 0b = No open load detected on OUT1 1b = Open load detected on OUT1 |
| 3 | OCP4 | R | 0b | 0b = No OCP detected on OUT4 1b = OCP detected on OUT4 |
| 2 | OCP3 | R | 0b | 0b = No OCP detected on OUT3 1b = OCP detected on OUT3 |
| 1 | OCP2 | R | 0b | 0b = No OCP detected on OUT2 1b = OCP detected on OUT2 |
| 0 | OCP1 | R | 0b | 0b = No OCP detected on OUT1 1b = OCP detected on OUT1 |