SNIU028E February 2016 – February 2025 UCD3138 , UCD3138064 , UCD3138064A , UCD3138128 , UCD3138A , UCD3138A64
Address 00040010
| 28 | 27 | 24 | 23 | 21 | 20 | 19 | 16 |
| SEQ7 _SH | SEQ7 | Reserved | SEQ6 _SH | SEQ6 | ||||||||
| R/W-0 | R/W-0000 | R-000 | R/W-0 | R/W-0000 | ||||||||
| 15 | 13 | 12 | 11 | 8 | 7 | 5 | 4 | 3 | 0 |
| Reserved | SEQ5 _SH | SEQ5 | Reserved | SEQ4 _SH | SEQ4 | ||||||||||
| R-000 | R/W-0 | R/W-0000 | R-000 | R/W-0 | R/W-0000 | ||||||||||
| LEGEND: R/W = Read/Write; R = Read only; -n = value after reset |
| Bit | Field | Type | Reset | Description |
|---|---|---|---|---|
| 28 | SEQ7_SH | R/W | 0 | Dual channel sequence select 0 = Not selected for Dual Sampling (Default) 1 = Selected for Dual Sampling |
| 27-24 | SEQ7 | R/W | 0000 | Channel to be converted eighth 0000 = ADC00 selected (Default) 0001 = ADC01 selected ……. 1111 = Temperature Sensor selected |
| 23-21 | Reserved | R | 000 | |
| 20 | SEQ6_SH | R/W | 0 | Dual channel sequence select 0 = Not selected for Dual Sampling (Default) 1 = Selected for Dual Sampling |
| 19-16 | SEQ6 | R/W | 0000 | Channel to be converted seventh 0000 = ADC00 selected (Default) 0001 = ADC01 selected ……. 1111 = Temperature Sensor selected |
| 15-13 | Reserved | R | 000 | |
| 12 | SEQ5_SH | R/W | 0 | Dual channel sequence select 0 = Not selected for Dual Sampling (Default) 1 = Selected for Dual Sampling |
| 11-8 | SEQ5 | R/W | 0000 | Channel to be converted sixth 0000 = ADC00 selected (Default) 0001 = ADC01 selected ……. 1111 = Temperature Sensor selected |
| 7-5 | Reserved | R | 000 | |
| 4 | SEQ4_SH | R/W | 0 | Dual channel sequence select 0 = Not selected for Dual Sampling (Default) 1 = Selected for Dual Sampling |
| 3-0 | SEQ4 | R/W | 0000 | Channel to be converted fifth 0000 = ADC00 selected (Default) 0001 = ADC01 selected ……. 1111 = Temperature Sensor selected |