SBAU488 June   2025 AMC23C15 , AMC3302

 

  1.   1
  2.   Description
  3.   Get Started
  4.   Features
  5.   Applications
  6.   6
  7. 1Evaluation Module Overview
    1. 1.1 Introduction
    2. 1.2 Kit Contents
    3. 1.3 Specification
    4. 1.4 Device Information
  8. 2Hardware
    1. 2.1 Hardware Overview
    2. 2.2 Assembly Instructions
    3. 2.3 Interfaces
      1. 2.3.1 Analog Input
      2. 2.3.2 Isolated Amplifier (AMC3302) Analog Output
      3. 2.3.3 Isolated Comparator (AMC23C15) Analog Output
    4. 2.4 Power Requirements
      1. 2.4.1 VDD2 Input
    5. 2.5 Test Points
    6. 2.6 Lug Information
    7. 2.7 Best Practices
  9. 3Implementation Results
    1. 3.1 Evaluation Procedure
      1. 3.1.1 Equipment Setup
      2. 3.1.2 Test Procedure
      3. 3.1.3 Full Signal Chain Evaluation Procedure
    2. 3.2 Performance Data and Results
      1. 3.2.1 Shunt Selection Calculations
      2. 3.2.2 Filter Selection
  10. 4Hardware Design Files
    1. 4.1 Schematics
    2. 4.2 PCB Layouts
    3. 4.3 Bill of Materials (BOM)
  11. 5Additional Information
    1. 5.1 Trademarks
  12. 6Related Documentation

Equipment Setup

  1. One 5V source limited to 50mA.
  2. High current electronic load (for example, Agilentâ„¢ N3300A).
  3. DC Current Source.
  4. High current carrying cables.
  5. One (or more) oscilloscopes or digital mulitmeters (DMM) with at least 6.5 digits of resolution. Optional: Use five DMMs for full signal chain evaluation.
  6. Signal generator or data collection equipment.
  7. Optional: High current supply control shunt for full signal chain evaluation.
AMC-AMP-200A-EVM Positive Current Equipment
                        SetupFigure 3-1 Positive Current Equipment Setup
AMC-AMP-200A-EVM Negative Current Equipment
                        SetupFigure 3-2 Negative Current Equipment Setup