SBAU488 June 2025 AMC23C15 , AMC3302
The AMC-AMP-200A-EVM has many hardware features, allowing the user to access and assess the EVM from many points in the signal chain. The default configuration is one 250µΩ shunt listed as R20 to sense ±200A applications.
This EVM is an example high current-sensing design and further designs can be modified per system requirements. Considerations included in definition table.
| 1. Vishay WSBS8518 Busbar Shunt Resistor |
|
| 2. Via Stitch | Via stitching provides aeration to dissipate heat further. |
| 3. AMC3302 Input | AMC3302 differential analog input. |
| 4. AMC23C15 Input | AMC23C15 analog input. |
| 5. Low-Side Power Supply | Low-side power supply connectors: terminal block J6 or test point connections. |
| 6. LED | LED on to indicate device powered. |
| 7. AMC3302 | Isolated current-sensing amplifier with integrated DC/DC converter. If smaller footprint desired or if high-side supply is available in the application such as from a gate driver or additional transformer winding, consider the AMC1302 isolated current-sensing amplifier. |
| 8. TLV9002 | Operational amplifier for differential to single-ended conversion. |
| 9. AMC23C15 |
|
| 10. AMC3302 Outputs | AMC3302 differential and single-ended outputs. |
| 11. AMC23C15 Outputs | AMC23C15 analog outputs. |