SDAA522 September   2026 ISO6020 , ISOM8110 , ISOM8110-Q1 , ISOM8113-Q1 , ISOM8610 , ISOM8710 , ISOW6441 , ISOW6442 , ISOW6442-Q1

 

  1.   1
  2.   Abstract
  3.   Trademarks
  4. 1 Introduction
    1. 1.1 Why Magnetic Field Immunity Matters for Isolators
  5. 2 Magnetic Field Units at a Glance
  6. 3 IEC 61000-4-8 — Power Frequency Magnetic Field Immunity
    1. 3.1 What IEC 61000-4-8 Test Simulates
    2. 3.2 Test Levels for IEC 61000-4-8 Continuous Power Frequency Fields
    3. 3.3 Environment Classes — How a Level is Chosen
    4. 3.4 Field Strengths Observed in Actual Installations
  7. 4 IEC 61000-4-9 — Pulse Magnetic Field Immunity
    1. 4.1 What IEC 61000-4-9 Test Simulates
    2. 4.2 Impulse Current Waveform for Pulse Magnetic Field
    3. 4.3 Test Levels for IEC 61000-4-9 Pulse Magnetic Fields
  8. 5 Summary of Class 5 Testing— What We Are Targeting
  9. 6 What "PASS" Means — Performance Criteria
  10. 7 Test Setup Details
  11. 8 Test Results and Summary
    1. 8.1 Test Conditions for Both Standards:
  12. 9 System Design Considerations for End Equipment Performance
  13. 10Summary
  14. 11References

Test Setup Details

A single, standalone isolation device is not exactly an "EUT" according to IEC 61000-4-8/9 standards — both the standards intend to test end equipment which gets installed in various harsh environments. To verify that TI's isolation devices can withstand Class 5 test levels and perform as per "Criteria A", the standalone devices are tested on the board without any magnetic shielding. This exposes the devices directly to the magnetic fields (per IEC 61000-4-8 and IEC 61000-4-9) generated by the induction coil connected to the test current generator as shown in Figure 7-1.

For monitoring device-level performance during the magnetic field testing, the DUT is mounted on an evaluation board and operated in a representative, continuously monitored functional loop:

  1. DUT board: A purpose-built characterization board, small enough to sit inside the maximum exposed area of the 1m × 1m coil.
  2. Input Signal: A known pattern (for example, a fixed-frequency square wave) driven into the input side.
  3. Output Monitoring: The isolated output signal/power is compared against the input in real time by a pattern checker / error counter, with an oscilloscope capturing any glitch.
  4. Power Supply: Both sides powered at nominal and at the extremes of the recommended operating range; isolated supply output monitored for devices with integrated DC/DC.
  5. Orientation: The board is rotated to expose the differential loops of the die to the field in all three axes. This matters because coupling is proportional to the loop area projected onto the field direction, so a single orientation is not a valid test.

 Test Setup for Magnetic Field
          Immunity

Figure 7-1 Test Setup for Magnetic Field Immunity