SLUSC82B April 2017 – July 2026 UCC24630
PRODUCTION DATA
In general, try to keep all high current loops as short as possible. Keep all high-current/high-frequency traces away from other traces in the design. If necessary, high-frequency/high-current traces must be perpendicular to signal traces, not parallel to them. Shielding signal traces with ground traces can help reduce noise pick up. Always consider appropriate clearances between the high-voltage connections and any low-voltage nets.