Do operate the device within the
recommended operating maximum parameters. Consider output overvoltage conditions
when determining stress.
Do consider the guideline for
setting the blanking time resistor value illustrated in Figure 6-6.
Do not use the UCC24630 with
converters that operate in constant skip cycle mode at high-power levels. The
skip cycle behavior results in numerous CCM faults and missing DRV pulses.
Do not use the UCC24630 in CCM
designs that are operating in CCM while the fly-back controller is operating in
variable frequency, FM, modulation. The CCM dead-time function is compatible
with CCM operation during fixed-frequency, PWM operation.
Do not use the UCC24630 in
hysteretic control CCM flyback converters. Constant skip-cycle operation at
high-power levels results in numerous CCM cycle faults resulting in efficiency
loss.