SLUSG22 October   2025 UCC35131-Q1

ADVANCE INFORMATION  

  1.   1
  2. 1 Features
  3. 2 Applications
  4. 3 Description
  5. 4 Device Comparison
  6. 5 Pin Configuration and Functions
  7. 6 Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 ESD Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information
    5. 6.5 Insulation Specifications
    6. 6.6 Electrical Characteristics
    7. 6.7 Safety-Related Certifications
  8. 7 Detailed Description
    1. 7.1 Overview
    2. 7.2 Pre-Production Samples Operating Limits
    3. 7.3 Functional Block Diagram
    4. 7.4 Feature Description
      1. 7.4.1 Power Stage Operation
        1. 7.4.1.1 VDD-COM Voltage Regulation
        2. 7.4.1.2 COM-VEE Voltage Regulation
      2. 7.4.2 Output Voltage Soft Start
      3. 7.4.3 ENA and Power-Good
      4. 7.4.4 Protection Functions
        1. 7.4.4.1 Input Undervoltage Lockout
        2. 7.4.4.2 Input Overvoltage Lockout
        3. 7.4.4.3 Output Undervoltage Protection
        4. 7.4.4.4 Output Overvoltage Protection
        5. 7.4.4.5 Over-Temperature Protection
        6. 7.4.4.6 BSW Pin Faults Protection
    5. 7.5 Device Functional Modes
  9. 8 Application and Implementation
    1. 8.1 Application Information
    2. 8.2 Typical Application
      1. 8.2.1 Design Requirements
      2. 8.2.2 Detailed Design Procedure
        1. 8.2.2.1 VDD-COM Voltage Regulation
        2. 8.2.2.2 COM-VEE Voltage Regulation and Single Output Configuration
    3. 8.3 System Examples
    4. 8.4 Power Supply Recommendations
    5. 8.5 Layout
      1. 8.5.1 Layout Guidelines
      2. 8.5.2 Layout Example
  10. 9 Device and Documentation Support
    1. 9.1 Third-Party Products Disclaimer
    2. 9.2 Documentation Support
      1. 9.2.1 Related Documentation
    3. 9.3 Receiving Notification of Documentation Updates
    4. 9.4 Support Resources
    5. 9.5 Trademarks
    6. 9.6 Electrostatic Discharge Caution
    7. 9.7 Glossary
  11. 10Revision History
  12. 11Mechanical, Packaging, and Orderable Information

Absolute Maximum Ratings

over operating free-air temperature range (unless otherwise noted)(1)
MIN TYP MAX UNIT
VVIN VIN to GNDP –0.3 30 V
VENA, VPG ENA, PG to GNDP –0.3 7 V
VFBVEE-COM FBVEE to COM -0.3 7 V
VBSW-COM BSW to COM -10 25.5 V
VBSW-VEE BSW to VEE -0.7 32 V
VBSW-VEE_tran BSW to VEE (0.24ns transient) -2.1 33.4 V
VCOM-VEE COM to VEE -0.3 10 V
VVDD-COM, VFBVDD-COM VDD,  FBVDD to COM –0.3 25.5 V
VVDD-VEE VDD to VEE –0.3 32 V
POUT_VDD_MAX Total output power at TA=25°C 3 W
TJ Operating junction temperature range –40 150 °C
Tstg Storage temperature –65 150 °C
Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.