The Board Offset calibration option is not offered in Battery Management Studio, because the Board Offset calibration is not required when using the BQ41Z50EVM.
- Connect and measure a -2A current source from 1N (–) and Pack– (+) to calibrate without using the FETs. (TI does not recommend calibration using the FETs).
- Enter –2000 in the Applied Current field and select the Calibrate Current box.
- Press the Calibrate Gas Gauge button to calibrate.
- Deselect the Calibrate Current box after current calibration has completed.