SLUUD92 June 2025 UCC218200-Q1
Board setup
Please plan jumpers as shown below (totally 5 jumpers).
Power supply set at 12V, 0.8A. Connect power supply to VHK_12V (power) and GND_HK (GND)
Tie OC_DST_HS to COM_HS, and OC_DST_LS to COM_LS. See diagram below for blue connection points
Probe the VCC-GND voltage between the VCC TP and any GND TP with a multimeter. This value should be 5V.
Probe the high side VDD-COM voltage by using the VDD TP and the COM TP from HS. Probe the low side VDD-COM voltage by using the VDD TP and the COM TP from LS. These values should be ~15V.
Probe the high side VEE-COM voltage by using the VEE TP and the COM TP. Probe the low side VEE-COM voltage by using the VEE TP and the COM TP. These values should be ~ -4V.
Make sure the 5V LED (green), the HS BIAS LED (RED), and the LS BIAS LED (RED) are on. Other than the 3 LEDs marked, no other LEDs should be ON.

Figure 4-1 Jumper Settings and Test Points