SLVSHH0 June 2026 TPS61290
PRODMIX
TPS61290x provides an active pulldown current to quickly discharge output when the EN is logic low or device in I2C shutdown mode. With this function, the output voltage is connected to ground through internal circuitry, preventing the output from “floating” or entering into an undetermined state. The output discharge function makes the power on and off sequencing smooth. Pay attention to the output discharge function if use this device in applications such as power multiplexing, because the output discharge circuitry creates a constant current path between the multiplexer output and the ground.
TPS61290x can modify the status of this function by writing the value of the DISCHG bit through I2C. When DISCHG = 0, disable output discharge function in I2C shutdown mode. When DISCHG = 1, enable output discharge function in shutdown mode. The default value of this bit is 1.