SLVSJD0 September 2026 DRV8003-Q1
PRODUCTION DATA
Overcurrent protection is available when ITRIP regulation is disabled. The output current for all drivers (OUT5-OUT12) is monitored, and after the blank time if current exceed the overcurrent threshold after for deglitch time, the output is disabled.
Disable ITRIP for OUT5 and OUT7 by configuring OUTx_ITRIP_EN = 0b in HS_REG_CNFG1 and for OUT6, OUT8-12 by configuring HS_OUTx_ITRIP_EN = 0b in HS_REG_CNFG3 register. Overcurrent thresholds are configured (high or low) by setting OUTx_RDSON_MODE bit for OUT5-7 and OUTx_OC_TH bits for OUT8-12 in HS_OC_CNFG register.
Blank time for overcurrent protection is 40μs for all high-side driver outputs. Blank time starts when OUTx is enabled. OUT5 and OUT7 have dedicated deglitch time settings, configurable via bits HS_OUT5_ITRIP_DG and OUT7_ITRIP_DG in the HS_REG_CNFG1 register. OUT6 has dedicated deglitch time settings, configurable via bits HS_OUT6_ITRIP_DG in the HS_REG_CNFG3 register. For OUT8-12 deglitch time settings are shared, configurable via bits HS_OUT_ITRIP_DG in the HS_REG_CNFG3 register. For VPVDD < 20V, all deglitch options (24, 32, 40, and 48μs) are available. For VPVDD > 20V the deglitch time is automatically reduced to 10μs. When overcurrent detection is detected, OUTx_OCP bit in HS_STAT register for OUT5-12 drivers is latched and the corresponding output is shutoff. The fault bit remains set until the CLR_FLT bit is asserted.