SLVSLK0 May   2026 TPSI8830

ADVANCE INFORMATION  

  1.   1
  2. 1 Features
  3. 2 Applications
  4. 3 Description
  5. 4 Device Comparison Table
  6. 5 Pin Configuration and Functions
  7. 6 Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 ESD Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information
    5. 6.5 Electrical Characteristics
    6. 6.6 Switching Characteristics
  8. 7 Parameter Measurement Information
  9. 8 Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
      1. 8.3.1 Configurable Fault Response Timer (TMR)
        1. 8.3.1.1 Fault Latch-OFF
        2. 8.3.1.2 Fault Auto-Retry
      2. 8.3.2 Over-Current Protection (OCP)
      3. 8.3.3 Thermal Shutdown
      4. 8.3.4 Zero-Cross Turn On
    4. 8.4 Device Functional Modes
  10. 9 Application and Implementation
    1. 9.1 Application Information
    2. 9.2 Typical Application
      1. 9.2.1 Thermostat
      2. 9.2.2 System Level Testing
      3. 9.2.3 Design Requirements
      4. 9.2.4 Detailed Design Procedure
    3. 9.3 Power Supply Recommendations
    4. 9.4 Layout
      1. 9.4.1 Layout Guidelines
        1. 9.4.1.1 EMI Considerations
      2. 9.4.2 Layout Example
  11. 10Device and Documentation Support
    1. 10.1 Third-Party Products Disclaimer
    2. 10.2 Receiving Notification of Documentation Updates
    3. 10.3 Support Resources
    4. 10.4 Trademarks
    5. 10.5 Electrostatic Discharge Caution
    6. 10.6 Glossary
  12. 11Revision History
  13. 12Mechanical, Packaging, and Orderable Information

Absolute Maximum Ratings

over operating free-air temperature range (unless otherwise noted)(1)
PARAMETER MIN MAX UNIT
VVDD Primary side supply voltage(2) –0.3 6 V
VFAULT FAULT pin voltage –0.3 6 V
VTMR TMR pin voltage –0.3 6 V
VEN Enable Voltage(2) –0.3 6 V
VS1,S2 Switch input voltage -87 87 V
TJ Junction temperature –40 150 °C
Tstg Storage temperature –65 150 °C
Transient Isolation Voltage AC Voltage, t = 60s 500 VRMS
DC Voltage, t = 60s 800 VDC
Operation outside the Absolute Maximum Ratings may cause permanent device damage. Absolute Maximum Ratings do not imply functional operation of the device at these or any other conditions beyond those listed under Recommended Operating Conditions. If used outside the Recommended Operating Conditions but within the Absolute Maximum Ratings, the device may not be fully functional, and this may affect device reliability, functionality, performance, and shorten the device lifetime.
Voltage values are with respect to GND.