SLVSLK0 May   2026 TPSI8830

ADVANCE INFORMATION  

  1.   1
  2. 1 Features
  3. 2 Applications
  4. 3 Description
  5. 4 Device Comparison Table
  6. 5 Pin Configuration and Functions
  7. 6 Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 ESD Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information
    5. 6.5 Electrical Characteristics
    6. 6.6 Switching Characteristics
  8. 7 Parameter Measurement Information
  9. 8 Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
      1. 8.3.1 Configurable Fault Response Timer (TMR)
        1. 8.3.1.1 Fault Latch-OFF
        2. 8.3.1.2 Fault Auto-Retry
      2. 8.3.2 Over-Current Protection (OCP)
      3. 8.3.3 Thermal Shutdown
      4. 8.3.4 Zero-Cross Turn On
    4. 8.4 Device Functional Modes
  10. 9 Application and Implementation
    1. 9.1 Application Information
    2. 9.2 Typical Application
      1. 9.2.1 Thermostat
      2. 9.2.2 System Level Testing
      3. 9.2.3 Design Requirements
      4. 9.2.4 Detailed Design Procedure
    3. 9.3 Power Supply Recommendations
    4. 9.4 Layout
      1. 9.4.1 Layout Guidelines
        1. 9.4.1.1 EMI Considerations
      2. 9.4.2 Layout Example
  11. 10Device and Documentation Support
    1. 10.1 Third-Party Products Disclaimer
    2. 10.2 Receiving Notification of Documentation Updates
    3. 10.3 Support Resources
    4. 10.4 Trademarks
    5. 10.5 Electrostatic Discharge Caution
    6. 10.6 Glossary
  12. 11Revision History
  13. 12Mechanical, Packaging, and Orderable Information

Switching Characteristics

Unless otherwise noted, all minimum/maximum specifications are over recommended operating conditions. All typical values are measured at TA = 25°C, VVDD = 5V, VEN = 5V.
MODE PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
SWITCHING CHARACTERISTICS
EN switching tPD_ON Input HI to Output voltage falling propagation delay VS1S2 = 24V RL = 48Ω 115 200 µs
tF Output fall time 40 TBD
tPD_OFF Input LO to Output voltage rising propagation delay 20 50
Fault Indication TFAULT Time between fault detected and FAULT asserting from OCP or TSD 500 µs
TRETRY Time between fault detected and enable auto-retry time TMR = 100pF 100 µs
TMR = 1nF 1 ms
TMR = 10nF 10 ms
TMR = 100nF 100 ms
TMR = 1uF 1 s
TMR = GND Latch-Off