SLVSLK0 May   2026 TPSI8830

ADVANCE INFORMATION  

  1.   1
  2. 1 Features
  3. 2 Applications
  4. 3 Description
  5. 4 Device Comparison Table
  6. 5 Pin Configuration and Functions
  7. 6 Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 ESD Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information
    5. 6.5 Electrical Characteristics
    6. 6.6 Switching Characteristics
  8. 7 Parameter Measurement Information
  9. 8 Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
      1. 8.3.1 Configurable Fault Response Timer (TMR)
        1. 8.3.1.1 Fault Latch-OFF
        2. 8.3.1.2 Fault Auto-Retry
      2. 8.3.2 Over-Current Protection (OCP)
      3. 8.3.3 Thermal Shutdown
      4. 8.3.4 Zero-Cross Turn On
    4. 8.4 Device Functional Modes
  10. 9 Application and Implementation
    1. 9.1 Application Information
    2. 9.2 Typical Application
      1. 9.2.1 Thermostat
      2. 9.2.2 System Level Testing
      3. 9.2.3 Design Requirements
      4. 9.2.4 Detailed Design Procedure
    3. 9.3 Power Supply Recommendations
    4. 9.4 Layout
      1. 9.4.1 Layout Guidelines
        1. 9.4.1.1 EMI Considerations
      2. 9.4.2 Layout Example
  11. 10Device and Documentation Support
    1. 10.1 Third-Party Products Disclaimer
    2. 10.2 Receiving Notification of Documentation Updates
    3. 10.3 Support Resources
    4. 10.4 Trademarks
    5. 10.5 Electrostatic Discharge Caution
    6. 10.6 Glossary
  12. 11Revision History
  13. 12Mechanical, Packaging, and Orderable Information

Electrical Characteristics

Unless otherwise noted, all minimum/maximum specifications are over recommended operating conditions. All typical values are measured at TA = 25°C, VVDD = 3.0V to 5.5V, VEN = 5V.
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
PRIMARY SIDE SUPPLY (VDD)
VUVLO VDD undervoltage threshold VDD rising 2.7 2.9 3.0 V
VDD falling 2.6 2.8 2.9 V
Hysteresis 100 120 130 mV
IVDD_ON VDD current, 3.3V, device powered on VVDD = 3.3V, VEN = VVDD V TJ = 25°C 5 6.2 mA
VVDD = 3.3V, VEN = VVDD  –40°C ≤ TJ ≤ 150°C 5 6.5
VDD current, 5.5V device powered on VVDD = 5.5V, VEN = VVDD, TJ = 25°C 4.5 5.2
VVDD = 5.5V, VEN = VVDD , –40°C ≤ TJ ≤ 150°C 4.5 6.5
IVDD_OFF VDD current, device powered off VEN = 0V TJ = 25°C 6 10 µA
VEN = 0V TJ = 85°C 6.3 11
VEN = 0V TJ = 105°C 7.6 15
VEN = 0V TJ = 125°C 30
FET CHARACTERISTICS 30mΩ
RDSON On resistance Connection A IO = 100mA, TJ = 25°C 30 35 mΩ
IO = 100mA, TJ = 85°C 43 50
IO = 100mA, TJ = 105°C 45 50
IO = 100mA, TJ = 125°C 45 55
IO = 100mA, –40°C ≤ TJ ≤ 150°C 60
On Resistance, Connection B IO = 100mA, TJ = 25°C 8 10 mΩ
IO = 100mA, TJ = 85°C 10 12
IO = 100mA, TJ = 105°C 10 15
IO = 100mA, TJ = 125°C 12 15
IO = 100mA, –40°C ≤ TJ ≤ 150°C 15
On resistance Connection C IO = 100mA, TJ = 25°C 15 20 mΩ
IO = 100mA, TJ = 85°C 20 25
IO = 100mA, TJ = 105°C 22 25
IO = 100mA, TJ = 125°C 25 30
IO = 100mA, –40°C ≤ TJ ≤ 150°C 30
IOFF_S1S2 Off leakage, 80V, Both Directions, Connection A VS1S2 = ±80V, TJ = 25°C 0.1 µA
VS1S2 = ±80V, TJ = 85°C 3
VS1S2 = ±80V, TJ = 105°C 5
VS1S2 = ±80V, TJ = 125°C 15
VS1S2 = ±80V, –40°C ≤ TJ ≤ 150°C 50
Off leakage, 60V, Both Directions, Connection A VS1S2 = ±60V, TJ = 25°C 0.1
VS1S2 = ±60V, TJ = 85°C 1
VS1S2 = ±60V, TJ = 105°C 3
VS1S2 = ±60V, TJ = 125°C 10
VS1S2 = ±60V, –40°C ≤ TJ ≤ 150°C 40
Off leakage, 24V, Both Directions, Connection A VS1S2 = ±24V, TJ = 25°C 0.1
VS1S2 = ±24V, TJ = 85°C 1
VS1S2 = ±24V, TJ = 105°C 1.5
VS1S2 = ±24V, TJ = 125°C 6
VS1S2 = ±24V, –40°C ≤ TJ ≤ 150°C 25
IOFF_S1S2 Off leakage, 80V, Connection B, C VS1S2 = +80V, TJ = 25°C 0.1 µA
VS1S2 = +80V, TJ = 85°C 4
VS1S2 = +80V, TJ = 105°C 10
VS1S2 = +80V, TJ = 125°C 30
VS1S2 = +80V, –40°C ≤ TJ ≤ 150°C 100
Off leakage, 60V, Connection B, C VS1S2 = +60V, TJ = 25°C 0.2
VS1S2 = +60V, TJ = 85°C 2
VS1S2 = +60V, TJ = 105°C 6
VS1S2 = +60V, TJ = 125°C 20
VS1S2 = +60V, –40°C ≤ TJ ≤ 150°C 80
Off leakage, 24V, Connection B, C VS1S2 = +24V, TJ = 25°C 0.2
VS1S2 = +24V, TJ = 85°C 1
VS1S2 = +24V, TJ = 105°C 3
VS1S2 = +24V, TJ = 125°C 12
VS1S2 = +24V, –40°C ≤ TJ ≤ 150°C 50
COSS S1, S2 capacitance VS1,S2 = 0V, SM float, F = 1MHz 75 pF
PROTECTION 30mΩ (TSD, OCP)
IOCP Over Current Protection Threshold Device Version A, Configuration A, V = ±80V 4 A
IOCP Over Current Protection Threshold Device Version B, Configuration A, V = ±80V 6 A
tOCP Over-Current Protection Response Time Current Slew Rate = 3A/µs 8 µs
CLoad Load capacitance without a false trip due to high inrush current. V = 80V 1.5 µF
TSD Thermal Shutdown 170 °C
ZERO CROSS
Zth Zero Cross Detection Threshold  Freq = 60Hz
VS = 24VAC, ILoad = 1ARMS
Switch is ON when IS1 = 50mA
-2.4 2.4 V
ZTpd Zero Cross Detection to turn on time 1000 us
LOGIC-LEVEL INPUT (EN)
VIL Input logic low voltage 0.0 0.65 V
VIH Input logic high voltage 0.95 5.5 V
VHYS Input logic hysteresis 100 250 300 mV
IIL Input logic low current VEN = 0V –0.1 0.1 µA
VEN = 0.8V 0.5 0.85 2.25 µA
IIH Input logic high current VEN = 5V 4 5.5 8 µA
IVDD_FS VDD fail-safe current VEN = 5V, VVDD = 0V –0.1 0 0.1 µA
RPD Pulldown resistance VEN = 0.6V 1000 kΩ
OPEN-DRAIN OUTPUTS(FAULT)
VOL_FLT Output Low Voltage IFAULT = 1mA 0.5 V
IOFF_FLT Off-state Leakage VFAULT = 5V 5e-05 1e-4 5 µA