SLVUD73 April 2025 TPS7H3014-SEP , TPS7H3014-SP
In the following tests, SENSE3 is tied to GND to prevent reaching the VON3 threshold before the Regulation Timer expires. Sequence DOWN is initiated automatically by the device when REG_TMR expires. This time is set by the jumper and resistor used on the REG_TMR pin. If REG_TMR is floating, the Regulation Timer does not expire, and the device waits indefinitely for a condition that changes the state.
Figure 3-9 Regulation Timer Expiration,
23ms
Figure 3-10 Regulation Timer Expiration,
12ms
Figure 3-11 Sequence UP, REG_TMR
Floating
Figure 3-12 Sequence DOWN, REG_TMR
Floating