Enable the TPS61371EVM board for operation by the following steps:
- Set J5 to the ON position. Turn on the power supply.
- Open the GUI.
- Select the Auto Connect button on the
bottom left corner of the page on the target address widget (Figure 3-2). The button
automatically checks for target addresses (0x72, 0x73, 0x74) and connects the
GUI with the device.
- Select the Start button. This button shows