SPRSPC3A February 2026 – August 2026 AM13E23019
ADVANCE INFORMATION
The two voltage monitors (POR and BOR) have to release their respective outputs before the device begins operation (that is, NRST goes high). However, if either of the voltage monitors trips, NRST is driven low. The I/Os are held in high impedance when any of the voltage monitors trip.
The POR monitor supervises the VDD rail. During power up, this is the first monitor to release (that is, first to untrip) on VDD.
The BOR monitor also supervises the VDD rail. During power up, this is the second monitor to release (that is, second to untrip) on VDD. This monitor has a tighter tolerance compared to the POR.
Any drop in voltage below the recommended operating voltages will trip the BOR and reset the device but this can be disabled by setting VMONCTL.bit.BORLVMONDIS to 1. The BOR can only be disabled after the device has fully booted up. If the BOR is disabled, the POR will reset the device for voltage drops.