TIDT408A
December 2024 – May 2025
1
Description
Features
Applications
1
Test Prerequisites
1.1
Voltage and Current Requirements
1.2
Required Equipment
1.3
Dimensions
1.4
Test Setup
2
Testing and Results
2.1
Efficiency Graphs
2.2
Voltage Regulation
2.3
No Load Power Consumption
2.4
Efficiency Data
2.5
Thermal Images
2.6
EMI
3
Waveforms
3.1
Start-Up and Shut Down Waveforms
3.2
Voltage Transition
3.3
Switching Waveform
3.3.1
Voltage Stress at Normal Operation
3.3.2
Voltage Stress at Start-Up
3.3.3
VCC Self-Bias Voltage
3.3.4
X Cap Discharge
3.4
Ripple and Noise
3.5
Load Transients
3.6
Overcurrent Protection
3.7
Short-Circuit Protection
3.8
Overvoltage Protection at AC-DC Output
1.2
Required Equipment
AC Source: Chroma Model 61601
Digital Power Meter: Yokogawa WT310
Power-Z P240 Bi-directional Multi-protocol Power Supply
DC source: GWinstek, GPS-3303C
Bi-Directional Power Source: IT6010C-80-300
Electronic load: Chroma, 6314A
Oscilloscope: Tektronix, DPO 3054
Infrared Thermal Camera: Fluke, TiS55
Ture-RMS-Multimeter: Fluke, 287C