Product type Analog output Common-mode voltage (max) (V) 80 Common-mode voltage (min) (V) 2.7 Input offset (±) (max) (µV) 25 Input offset drift (±) (typ) (µV/°C) 0.05 Features High frequency, Ultra precise Rating Space Voltage gain (V/V) 20 CMRR (min) (dB) 140 Bandwidth (kHz) 1100 Supply voltage (max) (V) 5.5 Supply voltage (min) (V) 2.7 Iq (max) (mA) 0.37 Number of channels 1 Comparators (#) 0 Gain error (%) 0.1 Gain error drift (±) (max) (ppm/°C) 5 Slew rate (V/µs) 2 Operating temperature range (°C) -55 to 125
Product type Analog output Common-mode voltage (max) (V) 80 Common-mode voltage (min) (V) 2.7 Input offset (±) (max) (µV) 25 Input offset drift (±) (typ) (µV/°C) 0.05 Features High frequency, Ultra precise Rating Space Voltage gain (V/V) 20 CMRR (min) (dB) 140 Bandwidth (kHz) 1100 Supply voltage (max) (V) 5.5 Supply voltage (min) (V) 2.7 Iq (max) (mA) 0.37 Number of channels 1 Comparators (#) 0 Gain error (%) 0.1 Gain error drift (±) (max) (ppm/°C) 5 Slew rate (V/µs) 2 Operating temperature range (°C) -55 to 125
TSSOP (PW) 8 19.2 mm² 3 x 6.4
  • VID V62/25635
  • Radiation - Total Ionizing Dose (TID):
    • TID performance assurance up to 30krad(Si)
    • Radiation Lot Acceptance Testing (RLAT) for every wafer lot up to 30krad(Si)
  • Radiation - Single-Event Effects (SEE):
    • Single Event Latch-Up (SEL) immune up to 43MeV-cm2 /mg at 125°C
    • Single Event Transient (SET) characterized up to LET = 47.5MeV-cm2 /mg
  • Space Enhanced Plastic
    • Operating temperature from –55°C to +125°C
    • Controlled baseline
    • Au bondwire and NiPdAu lead finish
    • Outgassing test performed per ASTM E595
    • One fabrication, assembly, and test site
    • Extended product life cycle
    • Product traceability
  • Wide common-mode voltage:
    • Operational voltage: 2.7V to 80V
    • Survival voltage: −20V to 85V
  • Excellent CMRR:
    • 160dB DC
    • 85dB AC at 50kHz
  • Gain of 20V/V
    • Gain error: ±0.1% (maximum)
    • Gain drift: ±1.5ppm/°C
  • Offset voltage: ±12µV (maximum)
  • Offset drift: ±0.05µV/°C
  • High bandwidth: 1.1MHz
  • Slew rate: 2V/µs
  • Quiescent current: 370µA
  • VID V62/25635
  • Radiation - Total Ionizing Dose (TID):
    • TID performance assurance up to 30krad(Si)
    • Radiation Lot Acceptance Testing (RLAT) for every wafer lot up to 30krad(Si)
  • Radiation - Single-Event Effects (SEE):
    • Single Event Latch-Up (SEL) immune up to 43MeV-cm2 /mg at 125°C
    • Single Event Transient (SET) characterized up to LET = 47.5MeV-cm2 /mg
  • Space Enhanced Plastic
    • Operating temperature from –55°C to +125°C
    • Controlled baseline
    • Au bondwire and NiPdAu lead finish
    • Outgassing test performed per ASTM E595
    • One fabrication, assembly, and test site
    • Extended product life cycle
    • Product traceability
  • Wide common-mode voltage:
    • Operational voltage: 2.7V to 80V
    • Survival voltage: −20V to 85V
  • Excellent CMRR:
    • 160dB DC
    • 85dB AC at 50kHz
  • Gain of 20V/V
    • Gain error: ±0.1% (maximum)
    • Gain drift: ±1.5ppm/°C
  • Offset voltage: ±12µV (maximum)
  • Offset drift: ±0.05µV/°C
  • High bandwidth: 1.1MHz
  • Slew rate: 2V/µs
  • Quiescent current: 370µA

The INA950-SEP is an ultra-precise, current-sense amplifier that can measure voltage drops across shunt resistors over a wide common-mode range from 2.7V to 80V. The ultra-precise current measurement accuracy is achieved thanks to the combination of an ultra-low offset voltage of ±12µV (maximum), a small gain error of ±0.1% (maximum), and a high DC CMRR of 160dB (typical). The INA950-SEP is not only designed for DC current measurement, but also for high-speed applications (such as fast overcurrent protection, for example) with a high bandwidth of 1.1MHz and an 85dB AC CMRR (at 50kHz).

The INA950-SEP provides the capability to make ultra-precise current measurements by sensing the voltage drop across a shunt resistor over a wide common- mode range from 2.7V to 80V. The INA950-SEP is available in the TSSOP-8 package.

The INA950-SEP operates from a single 2.7V to 5.5V supply while only drawing 370µA from the supply (typical). The low offset of the zero-drift architecture enables current sensing with low ohmic shunts as specified over the operating temperature range (−55°C to 125°C).

The INA950-SEP is an ultra-precise, current-sense amplifier that can measure voltage drops across shunt resistors over a wide common-mode range from 2.7V to 80V. The ultra-precise current measurement accuracy is achieved thanks to the combination of an ultra-low offset voltage of ±12µV (maximum), a small gain error of ±0.1% (maximum), and a high DC CMRR of 160dB (typical). The INA950-SEP is not only designed for DC current measurement, but also for high-speed applications (such as fast overcurrent protection, for example) with a high bandwidth of 1.1MHz and an 85dB AC CMRR (at 50kHz).

The INA950-SEP provides the capability to make ultra-precise current measurements by sensing the voltage drop across a shunt resistor over a wide common- mode range from 2.7V to 80V. The INA950-SEP is available in the TSSOP-8 package.

The INA950-SEP operates from a single 2.7V to 5.5V supply while only drawing 370µA from the supply (typical). The low offset of the zero-drift architecture enables current sensing with low ohmic shunts as specified over the operating temperature range (−55°C to 125°C).

Herunterladen Video mit Transkript ansehen Video

Technische Dokumentation

star =Von TI ausgewählte Top-Empfehlungen für dieses Produkt
Keine Ergebnisse gefunden. Bitte geben Sie einen anderen Begriff ein und versuchen Sie es erneut.
Alle anzeigen 6
Top-Dokumentation Typ Titel Format-Optionen Datum
* Data sheet INA950-SEP 2.7V to 80V, 1.1MHz, Ultra-Precise, Current-Sense Amplifier datasheet PDF | HTML 11 Mär 2025
* Radiation & reliability report INA950-SEP Total Ionizing Dose (TID) Report (Rev. A) 14 Mär 2025
* Radiation & reliability report INA950-SEP Single-Event Effects (SEE) Radiation Test Report (Rev. B) PDF | HTML 13 Mär 2025
* Radiation & reliability report INA950-SEP Production Flow and Reliability Report PDF | HTML 27 Feb 2025
Application brief Precision High-Voltage Current Sensing Using Zener-Shifted Floating Ground and Isolated Digital Interface PDF | HTML 10 Dez 2025
Selection guide TI Space Products (Rev. K) 04 Apr 2025

Design und Entwicklung

Weitere Bedingungen oder erforderliche Ressourcen enthält gegebenenfalls die Detailseite, die Sie durch Klicken auf einen der unten stehenden Titel erreichen.

Simulationsmodell

INA950-SEP PSpice Model Reference

SBOMCN0.ZIP (1160 KB) - PSpice Model
Simulationsmodell

INA950-SEP Spice Model

SWCM009.ZIP (59 KB) - TISpice Model
Berechnungstool

ANALOG-ENGINEER-CALC PC software analog engineer's calculator

The analog engineer’s calculator is designed to speed up many of the repetitive calculations that analog circuit design engineers use on a regular basis. This PC-based tool provides a graphical interface with a list of various common calculations ranging from setting operational-amplifier (...)

Unterstützte Produkte und Hardware

Unterstützte Produkte und Hardware

Designtool

CIRCUIT060035 — Bidirektionale Strommessung mit einem Fensterkomparatorschaltkreis

Diese bidirektionale Strommesslösung verwendet einen Strommessverstärker und einen Hochgeschwindigkeits-Doppelkomparator mit einem Gleichtaktbereich am Rail-to-Rail-Eingang, um Überstrom-Alarmsignale (OC) an den Komparatorausgängen (OUTA und OUTB) zu erzeugen, wenn der Eingangsstrom (IG1) über (...)
Designtool

CIRCUIT060037 — Präziser Überstrom-Haltespeicher-Schaltkreis

Diese High-Side-Strommesslösung verwendet einen Strommessverstärker, einen Komparator mit integrierter Referenz und einen P-Kanal-MOSFET, um einen Überstrom-Latch-Schaltkreis zu erschaffen. Wenn ein Laststrom erkannt wird, welcher größer ist als 200 mA, trennt der Schaltkreis das System von seiner (...)
Simulationstool

PSPICE-FOR-TI — PSpice® für TI Design-und Simulationstool

PSpice® für TI ist eine Design- und Simulationsumgebung, welche Sie dabei unterstützt, die Funktionalität analoger Schaltungen zu evaluieren. Diese Design- und Simulationssuite mit vollem Funktionsumfang verwendet eine analoge Analyse-Engine von Cadence®. PSpice für TI ist kostenlos erhältlich und (...)
Simulationstool

TINA-TI — SPICE-basiertes analoges Simulationsprogramm

TINA-TI provides all the conventional DC, transient and frequency domain analysis of SPICE and much more. TINA has extensive post-processing capability that allows you to format results the way you want them. Virtual instruments allow you to select input waveforms and probe circuit nodes voltages (...)
Benutzerhandbuch: PDF
Gehäuse Pins CAD-Symbole, Footprints und 3D-Modelle
TSSOP (PW) 8 Ultra Librarian

Bestellen & Qualität

Beinhaltete Information:
  • RoHS
  • REACH
  • Bausteinkennzeichnung
  • Blei-Finish/Ball-Material
  • MSL-Rating / Spitzenrückfluss
  • MTBF-/FIT-Schätzungen
  • Materialinhalt
  • Qualifikationszusammenfassung
  • Kontinuierliches Zuverlässigkeitsmonitoring
Beinhaltete Information:
  • Werksstandort
  • Montagestandort

Support und Schulungen

TI E2E™-Foren mit technischem Support von TI-Ingenieuren

Inhalte werden ohne Gewähr von TI und der Community bereitgestellt. Sie stellen keine Spezifikationen von TI dar. Siehe Nutzungsbedingungen.

Bei Fragen zu den Themen Qualität, Gehäuse oder Bestellung von TI-Produkten siehe TI-Support. ​​​​​​​​​​​​​​

Videos