AFE4900

ACTIVO

AFE integrado de potencia ultrabaja para la detección biológica óptica portátil eléctrica

Detalles del producto

Applications 1-lead ECG, Optical-HRM Number of input channels 3 Resolution (Bits) 22 Number of LEDs 4 Interface type I2C, SPI Operating temperature range (°C) -20 to 70 Rating Catalog
Applications 1-lead ECG, Optical-HRM Number of input channels 3 Resolution (Bits) 22 Number of LEDs 4 Interface type I2C, SPI Operating temperature range (°C) -20 to 70 Rating Catalog
DSBGA (YZ) 30 4.8 mm² 2.4 x 2
  • Synchronized PPG, ECG signal acquisition at data rates up to 1 kHz
  • ECG signal chain:
    • Standalone ECG acquisition up to 4 kHz
    • Input bias: 1-lead ECG with RLD bias
    • Programmable INA gain: 2.15 to 12.92
    • Input noise (1 Hz to 150 Hz): 2.5 µVrms at 1 kHz, 1.25 µVrms at 4-kHz data rate
    • AC, DC lead-off detect: 12.5-nA to 100-nA
    • IEC 60601 Test report available on request
  • PPG receiver:
    • Supports three time-multiplexed PD inputs
    • 24-Bit representation of current from PD
    • DC offset subtraction DAC (Up to ±126-µA) at TIA input for each LED, ambient
    • Digital ambient subtraction at ADC output
    • Noise filtering with programmable bandwidth
    • Transimpedance gain: 10 kΩ to 2 MΩ
    • Dynamic range up to 100 dB
    • Receiver operates in PPG-only mode at approximately 1-µA/Hz sampling rate
    • Power-down mode: approximately 0 µA
  • PPG transmitter:
    • Four LEDs in common anode configuration
    • 8-Bit LED current up to 200 mA
    • Mode to fire two LEDs in parallel
    • Programmable LED on-time
    • Simultaneous support of three LEDs for SpO2, or multiwavelength HRM
    • Average current of 30 µA adequate for a
      typical heart-rate monitoring scenario:
      • 20-mA Setting, 60-µs pulse duration,
        25-Hz sampling rate
  • Clocking using an external or internal clock
  • FIFO with 128-sample depth for ECG and PPG
  • I2C, SPI interfaces: selectable by pin
  • 2.6-mm × 2.1-mm, 0.4-mm Pitch DSBGA package
  • Supplies:
    • Rx: 1.8 V to 1.9 V (LDO bypass),
      2.0 V to 3.6 V (LDO enabled)
    • Tx: 3 V to 5.25 V
    • IO: 1.7 V to Rx_SUP
  • Synchronized PPG, ECG signal acquisition at data rates up to 1 kHz
  • ECG signal chain:
    • Standalone ECG acquisition up to 4 kHz
    • Input bias: 1-lead ECG with RLD bias
    • Programmable INA gain: 2.15 to 12.92
    • Input noise (1 Hz to 150 Hz): 2.5 µVrms at 1 kHz, 1.25 µVrms at 4-kHz data rate
    • AC, DC lead-off detect: 12.5-nA to 100-nA
    • IEC 60601 Test report available on request
  • PPG receiver:
    • Supports three time-multiplexed PD inputs
    • 24-Bit representation of current from PD
    • DC offset subtraction DAC (Up to ±126-µA) at TIA input for each LED, ambient
    • Digital ambient subtraction at ADC output
    • Noise filtering with programmable bandwidth
    • Transimpedance gain: 10 kΩ to 2 MΩ
    • Dynamic range up to 100 dB
    • Receiver operates in PPG-only mode at approximately 1-µA/Hz sampling rate
    • Power-down mode: approximately 0 µA
  • PPG transmitter:
    • Four LEDs in common anode configuration
    • 8-Bit LED current up to 200 mA
    • Mode to fire two LEDs in parallel
    • Programmable LED on-time
    • Simultaneous support of three LEDs for SpO2, or multiwavelength HRM
    • Average current of 30 µA adequate for a
      typical heart-rate monitoring scenario:
      • 20-mA Setting, 60-µs pulse duration,
        25-Hz sampling rate
  • Clocking using an external or internal clock
  • FIFO with 128-sample depth for ECG and PPG
  • I2C, SPI interfaces: selectable by pin
  • 2.6-mm × 2.1-mm, 0.4-mm Pitch DSBGA package
  • Supplies:
    • Rx: 1.8 V to 1.9 V (LDO bypass),
      2.0 V to 3.6 V (LDO enabled)
    • Tx: 3 V to 5.25 V
    • IO: 1.7 V to Rx_SUP

The AFE4900 device is an analog front-end (AFE) for synchronized electrocardiogram (ECG), photoplethysmogram (PPG) signal acquisition. The device can also be used for optical bio-sensing applications, such as heart-rate monitoring (HRM) and saturation of peripheral capillary oxygen (SpO2). The PPG signal chain supports up to four switching light-emitting diodes (LEDs) and up to three photodiodes (PDs). The LEDs can be switched on using a fully integrated LED driver. The current from the photodiode is converted into voltage by the transimpedance amplifier (TIA) and digitized using an analog-to-digital converter (ADC). The ECG signal chain has an instrumentation amplifier (INA) with a programmable gain that interfaces to the same ADC. A right-leg drive (RLD) amplifier set can be used to the bias for the ECG input pins. AC and dc lead-off detect schemes are supported. The ADC codes from the PPG and ECG phases can be stored in a 128-sample first in, first out (FIFO) block and read out using either an I2C or a serial programming interface (SPI) interface.

The AFE4900 device is an analog front-end (AFE) for synchronized electrocardiogram (ECG), photoplethysmogram (PPG) signal acquisition. The device can also be used for optical bio-sensing applications, such as heart-rate monitoring (HRM) and saturation of peripheral capillary oxygen (SpO2). The PPG signal chain supports up to four switching light-emitting diodes (LEDs) and up to three photodiodes (PDs). The LEDs can be switched on using a fully integrated LED driver. The current from the photodiode is converted into voltage by the transimpedance amplifier (TIA) and digitized using an analog-to-digital converter (ADC). The ECG signal chain has an instrumentation amplifier (INA) with a programmable gain that interfaces to the same ADC. A right-leg drive (RLD) amplifier set can be used to the bias for the ECG input pins. AC and dc lead-off detect schemes are supported. The ADC codes from the PPG and ECG phases can be stored in a 128-sample first in, first out (FIFO) block and read out using either an I2C or a serial programming interface (SPI) interface.

Descargar Ver vídeo con transcripción Video

Más información

La hoja de datos completa y otros recursos de diseño están disponibles bajo NDA. Solicitar ahora

Productos similares que pueden interesarle

open-in-new Comparar alternativas
Misma funcionalidad con diferente configuración de pines que el dispositivo comparado
AFE4950 ACTIVO AFE integrado ultrapequeño para la monitorización óptica portátil de la frecuencia cardiaca y SpO2 ECG+PPG AFE with integrated high-pass, low-pass filters optimized for dry electrodes.

Documentación técnica

star =Principal documentación para este producto seleccionada por TI
No se encontraron resultados. Borre su búsqueda y vuelva a intentarlo.
Ver todo 3
Tipo Título Fecha
* Data sheet AFE4900 Ultra-low Power, Integrated AFE for Wearable Optical, Electrical Bio-sensing with FIFO datasheet (Rev. B) PDF | HTML 30 jul 2019
Technical article Designing compact, efficient and high performing multiparameter patient monitors PDF | HTML 25 jun 2019
Technical article No strings attached: Creating next-generation wireless patient monitors PDF | HTML 29 jun 2018

Diseño y desarrollo

Para conocer los términos adicionales o los recursos necesarios, haga clic en cualquier título de abajo para ver la página de detalles cuando esté disponible.

Placa de evaluación

AFE4403EVM — AFE integrado AFE4403 para módulo de evaluación de monitores de frecuencia cardiaca y pulsioxímetros

The AFE4403EVM is intended for evaluating the AFE4403 device. The fully integrated AFE is ideally suited for Pulse Oximeter and Heart rate monitoring applications and consists of low noise receive channel, the LED transmit section and diagnostics for sensor and LED fault detection. The AFE4403 has (...)

Guía del usuario: PDF
Placa de evaluación

AFE4490SPO2EVM — Extremo frontal analógico integrado (AFE) AFE4490 para módulo de evaluación de pulsioxímetros

The AFE44x0SPO2EVM is intended for evaluating AFE4400 and AFE4490 devices. The family of devices are fully integrated AFE ideally suited for Pulse Oximeter applications and consist of low noise receive channel, the LED transmit section and diagnostics for sensor and LED fault detection. The (...)

Guía del usuario: PDF
Placa de evaluación

AFE4900EVM — AFE integrado de potencia ultrabaja AFE4900 para módulo de evaluación de detección biológica óptica

The AFE4900 is an analog front end (AFE) for optical biosensing applications, such as heart-rate monitoring (HRM) and saturation of peripheral capillary oxygen (SpO2). The device supports four switching light-emitting diodes (LEDs) and three photodiodes. The current from the photodiode is converted (...)

Herramienta de simulación

PSPICE-FOR-TI — PSpice® para herramienta de diseño y simulación de TI

PSpice® for TI is a design and simulation environment that helps evaluate functionality of analog circuits. This full-featured, design and simulation suite uses an analog analysis engine from Cadence®. Available at no cost, PSpice for TI includes one of the largest model libraries in the (...)
Diseños de referencia

TIDA-01580 — Diseño de referencia de monitor inalámbrico de frecuencia cardíaca, ECG, SpO2 y PTT para dispositivo

This reference design is a simple, wearable, multi-parameter, patient monitor that uses a single-chip, biosensing front end, AFE4900, for synchronized electrocardiography (ECG) and photoplethysmography (PPG) measurements. The measured data is transferred to a remote location using CC2640R2F (...)
Design guide: PDF
Esquema: PDF
Paquete Pasadores Descargar
DSBGA (YZ) 30 Ver opciones

Pedidos y calidad

Información incluida:
  • RoHS
  • REACH
  • Marcado del dispositivo
  • Acabado de plomo/material de la bola
  • Clasificación de nivel de sensibilidad a la humedad (MSL) / reflujo máximo
  • Estimaciones de tiempo medio entre fallas (MTBF)/fallas en el tiempo (FIT)
  • Contenido del material
  • Resumen de calificaciones
  • Monitoreo continuo de confiabilidad
Información incluida:
  • Lugar de fabricación
  • Lugar de ensamblaje

Los productos recomendados pueden tener parámetros, módulos de evaluación o diseños de referencia relacionados con este producto de TI.

Soporte y capacitación

Foros de TI E2E™ con asistencia técnica de los ingenieros de TI

El contenido lo proporcionan “tal como está” TI y los colaboradores de la comunidad y no constituye especificaciones de TI. Consulte los términos de uso.

Si tiene preguntas sobre la calidad, el paquete o el pedido de productos de TI, consulte el soporte de TI. ​​​​​​​​​​​​​​

Videos