Amplificador de instrumentación de baja potencia (110 µA) con amplificador de referencia integrado p

Detalles del producto

Number of channels 1 Vs (max) (V) 5.5 Vs (min) (V) 1.8 Input offset (±) (max) (µV) 1300 Voltage gain (min) (V/V) 10 Voltage gain (max) (V/V) 50 Noise at 1 kHz (typ) (nV√Hz) 36 Features Cost Optimized, Low power, Small Size CMRR (min) (dB) 86 Iq (typ) (mA) 0.11 Bandwidth at min gain (typ) (MHz) 0.1 Gain error (±) (max) (%) 0.1 Operating temperature range (°C) -40 to 125 Rating Catalog Output swing headroom (to negative supply) (typ) (V) 0.015 Output swing headroom (to positive supply) (typ) (V) 0.015 Input common mode headroom (to negative supply) (typ) (V) 0 Input common mode headroom (to positive supply) (typ) (V) 0 Noise at 0.1 Hz to 10 Hz (typ) (µVPP) 3.2
Number of channels 1 Vs (max) (V) 5.5 Vs (min) (V) 1.8 Input offset (±) (max) (µV) 1300 Voltage gain (min) (V/V) 10 Voltage gain (max) (V/V) 50 Noise at 1 kHz (typ) (nV√Hz) 36 Features Cost Optimized, Low power, Small Size CMRR (min) (dB) 86 Iq (typ) (mA) 0.11 Bandwidth at min gain (typ) (MHz) 0.1 Gain error (±) (max) (%) 0.1 Operating temperature range (°C) -40 to 125 Rating Catalog Output swing headroom (to negative supply) (typ) (V) 0.015 Output swing headroom (to positive supply) (typ) (V) 0.015 Input common mode headroom (to negative supply) (typ) (V) 0 Input common mode headroom (to positive supply) (typ) (V) 0 Noise at 0.1 Hz to 10 Hz (typ) (µVPP) 3.2
WSON (DSG) 8 4 mm² (2 mm × 2 mm)
  • Fixed gain of 10V/V instrumentation amp with configurable reference amp
  • INA performance for 10-bit to 14-bit systems
    • CMRR: 95 dB (typical)
    • Gain error: 0.015% (typical)
    • Bandwidth: 100 kHz (typical)
  • Reference amp can be used for:
    • External DC error calibration with servo loop
    • Providing buffered voltage of external circuits
    • Filtering or adjustment of reference voltage
  • Ultra-small package option (2mm x 2mm)
  • Drives 1 nF with under 10% overshoot (typical)
  • Optimized quiescent current: 110 µA (typical)
  • Supply range: 1.8 V (±0.9 V) to 5.5 V (±2.75 V)
  • Specified temperature range: –40°C to 125°C
  • Fixed gain of 10V/V instrumentation amp with configurable reference amp
  • INA performance for 10-bit to 14-bit systems
    • CMRR: 95 dB (typical)
    • Gain error: 0.015% (typical)
    • Bandwidth: 100 kHz (typical)
  • Reference amp can be used for:
    • External DC error calibration with servo loop
    • Providing buffered voltage of external circuits
    • Filtering or adjustment of reference voltage
  • Ultra-small package option (2mm x 2mm)
  • Drives 1 nF with under 10% overshoot (typical)
  • Optimized quiescent current: 110 µA (typical)
  • Supply range: 1.8 V (±0.9 V) to 5.5 V (±2.75 V)
  • Specified temperature range: –40°C to 125°C

INA351A is a fixed gain of 10 instrumentation amplifier with a configurable reference amplifier in a small package. This instrumentation amp (INA) is built with precision-matched resistors to achieve excellent CMRR and gain error performance in a small, low-cost form factor. This makes INA351A a great solution to replace discrete INA implementations to achieve higher performance and more compact designs with minimal impact to bill of materials (BOM) costs.

The integrated, configurable reference amplifier can be used as a buffer for external use or as part of a closed-loop calibration circuit to achieve better DC precision. The closed-loop calibration can be accomplished by implementing a servo loop amplifier to calibrate DC errors from sensors (like offset, offset drift and so forth) at the INA output when the INA input signal is at a slightly higher frequency than DC depending on the application.

INA351A achieves 86 dB of minimum CMRR, an accurate 0.1% of maximum gain error and only consumes a maximum of 135 µA quiescent current at room temperature. The INA can directly drive sub-1 kHz, 10-bit to 14-bit, delta-sigma analog-to-digital converters (ADC) without an ADC driver, making it a great choice for portable, battery-powered medical applications like electrocardiograms or wearable health monitors.

INA351A is a fixed gain of 10 instrumentation amplifier with a configurable reference amplifier in a small package. This instrumentation amp (INA) is built with precision-matched resistors to achieve excellent CMRR and gain error performance in a small, low-cost form factor. This makes INA351A a great solution to replace discrete INA implementations to achieve higher performance and more compact designs with minimal impact to bill of materials (BOM) costs.

The integrated, configurable reference amplifier can be used as a buffer for external use or as part of a closed-loop calibration circuit to achieve better DC precision. The closed-loop calibration can be accomplished by implementing a servo loop amplifier to calibrate DC errors from sensors (like offset, offset drift and so forth) at the INA output when the INA input signal is at a slightly higher frequency than DC depending on the application.

INA351A achieves 86 dB of minimum CMRR, an accurate 0.1% of maximum gain error and only consumes a maximum of 135 µA quiescent current at room temperature. The INA can directly drive sub-1 kHz, 10-bit to 14-bit, delta-sigma analog-to-digital converters (ADC) without an ADC driver, making it a great choice for portable, battery-powered medical applications like electrocardiograms or wearable health monitors.

Descargar Ver vídeo con transcripción Video

Documentación técnica

No se encontraron resultados. Borre su búsqueda y vuelva a intentarlo.
Ver todo 1
Documentación principal Tipo Título Opciones de formato Descargar la versión más reciente en inglés Fecha
* Hoja de datos INA351A - Low Power, 1.8-V to 5.5-V Small-Size Instrumentation Amplifier with Configurable Reference Amplifier datasheet PDF | HTML 12/06/2023

Diseño y desarrollo

Para conocer los términos adicionales o los recursos necesarios, haga clic en cualquier título de abajo para ver la página de detalles cuando esté disponible.

Placa de evaluación

SMALL-AMP-DIP-EVM — Módulo de evaluación para amplificadores operacionales en encapsulados de pequeño tamaño

El SMALL-AMP-DIP-EVM acelera la creación de prototipos de amplificadores operativos de encapsulados pequeños, ya que proporciona una forma rápida y fácil de interactuar con muchos encapsulados de tamaño pequeño estándar de la industria. SMALL-AMP-DIP-EVM admite ocho opciones de encapsulados (...)

Guía del usuario: PDF
Productos y hardware compatibles
En inventario
Límite:
??asset.out-of-stock-ti_es_MX??
No disponible
Modelo de simulación

INA351A PSpice Reference Design

SBOMCE8.ZIP (7 KB) - Modelo PSpice
Productos y hardware compatibles
Modelo de simulación

INA351A TINA-TI Reference Design

SBOMCE7 (48 KB) - Diseño de referencia TINA-TI
Productos y hardware compatibles
Modelo de simulación

INA351A TINA-TI SPICE Model

SBOMCE9.ZIP (7 KB) - Modelo TINA-TI Spice
Productos y hardware compatibles
Herramienta de cálculo

ANALOG-ENGINEER-CALC — PC software analog engineer's calculator

La calculadora del ingeniero analógico está diseñada para acelerar muchos de los cálculos repetitivos que los ingenieros de diseño de circuitos analógicos utilizan de forma habitual. Esta herramienta para PC proporciona una interfaz gráfica con una lista de varios cálculos comunes que van desde el (...)

Productos y hardware compatibles
Encapsulado Pines Símbolos CAD, huellas y modelos 3D
WSON (DSG) 8 Ultra Librarian

Pedidos y calidad

Soporte y capacitación

Foros de TI E2E™ con asistencia técnica de los ingenieros de TI

El contenido lo proporcionan “tal como está” TI y los colaboradores de la comunidad y no constituye especificaciones de TI. Consulte los términos de uso.

Si tiene alguna pregunta sobre calidad, encapsulados o pedido de productos de TI, consulte el servicio de asistencia de TI. ​​​​​​​​​​​​​​

Videos