PGA305
Acondicionador de señal para sensores resistivos con salidas digitales y analógicas
PGA305
- Analog Features
- Analog Front-End for Resistive Bridge Sensors
- Accommodates Sensor Sensitivities From 1 mV/V to 135 mV/V
- On-Chip Temperature Sensor
- Programmable Gain
- 24-Bit Sigma-Delta Analog-to-Digital Converter for Signal Channel
- 24-Bit Sigma-Delta Analog-to-Digital Converter for Temperature Channel
- 14-Bit Output DAC
- Digital Features
- < 0.1% FSO Accuracy Across Temperature
- System Response Time < 220 µs
- Third-Order Offset, Gain, and Nonlinearity Temperature Compensation
- Diagnostic Functions
- Integrated EEPROM for Device Operation, Calibration Data and User Data
- Peripheral Features
- I2C interface for Data Reading and Device Configuration
- One-Wire Interface Enables Communication Through the Power Supply Pin Without Using Additional Lines
- 4-mA to 20-mA Current Loop Interface
- Ratiometric and Absolute Voltage Output
- Power Management Control
- Analog Low-Voltage Detect
- General Features
- Industrial Temperature Range: –40°C to 150°C
- Power Supply:
- On-Chip Power Management Accepts Wide Power-Supply Voltage From 3.3 V to 30 V
- Integrated Reverse-Protection Circuit
The PGA305 device supplies an interface for piezoresistive and strain-gauge pressure-sense elements. The device is a full system-on-chip (SoC) solution that includes programmable analog front end (AFE), ADC, and digital signal processing that enable direct connection to the sense element. The PGA305 device also includes integrated voltage regulators and an oscillator to minimize the number of external components. The PGA305 device can employ third-order temperature and nonlinearity compensation to achieve high accuracy. The device can also use the integrated I2C interface or the one-wire serial interface (OWI) to achieve external communication and simplify the system calibration process. An Integrated DAC supports absolute-voltage, ratiometric-voltage, and 4-mA to 20-mA current-loop outputs.
Documentación técnica
Tipo | Título | Fecha | ||
---|---|---|---|---|
* | Data sheet | PGA305 Signal Conditioner and Transmitter for Pressure Sensors datasheet | PDF | HTML | 29 ago 2017 |
EVM User's guide | PGAxxxEVM-034 User’s Guide (Rev. B) | 01 ago 2018 | ||
Application brief | PGA900, PGA300 and PGA305 Use Case for HVAC Applications | 02 may 2017 | ||
Application brief | PGA900, PGA300 and PGA305 Use Case for the Pressure Transmitter Applications | 02 may 2017 | ||
Application brief | PGA900, PGA300 and PGA305 Use Case for Weight Scale (Load Cell) Applications | 01 may 2017 |
Diseño y desarrollo
Para conocer los términos adicionales o los recursos necesarios, haga clic en cualquier título de abajo para ver la página de detalles cuando esté disponible.
PGA305EVM-034 — Módulo de evaluación del acondicionador de señal para sensores resistivos PGA305
Paquete | Pasadores | Descargar |
---|---|---|
VQFN (RHH) | 36 | Ver opciones |
Pedidos y calidad
- RoHS
- REACH
- Marcado del dispositivo
- Acabado de plomo/material de la bola
- Clasificación de nivel de sensibilidad a la humedad (MSL) / reflujo máximo
- Estimaciones de tiempo medio entre fallas (MTBF)/fallas en el tiempo (FIT)
- Contenido del material
- Resumen de calificaciones
- Monitoreo continuo de confiabilidad
- Lugar de fabricación
- Lugar de ensamblaje
Los productos recomendados pueden tener parámetros, módulos de evaluación o diseños de referencia relacionados con este producto de TI.
Soporte y capacitación
Foros de TI E2E™ con asistencia técnica de los ingenieros de TI
El contenido lo proporcionan “tal como está” TI y los colaboradores de la comunidad y no constituye especificaciones de TI. Consulte los términos de uso.
Si tiene preguntas sobre la calidad, el paquete o el pedido de productos de TI, consulte el soporte de TI.