ホーム インターフェイス RS-485 と RS-422 の各トランシーバ

SN65HVD96

アクティブ

SymPol トランシーバ

製品詳細

Number of receivers 1 Number of transmitters 1 Duplex Half Signaling rate (max) (Mbps) 5 Fault protection (V) -35 to 40 Common-mode range (V) -7 to 12 Number of nodes 32 Isolated No Supply current (max) (µA) 20000 Rating Catalog Operating temperature range (°C) -40 to 85
Number of receivers 1 Number of transmitters 1 Duplex Half Signaling rate (max) (Mbps) 5 Fault protection (V) -35 to 40 Common-mode range (V) -7 to 12 Number of nodes 32 Isolated No Supply current (max) (µA) 20000 Rating Catalog Operating temperature range (°C) -40 to 85
SOIC (D) 8 29.4 mm² (4.9 mm × 6 mm)
  • Communicate Without Errors on Normal or Reversed-Wire Bus Lines
  • Up to 5 Mbps Signaling
  • Industrial Temperature Range: –40°C to 85°C
  • Symmetric Polarity Receiver
  • Receiver Hysteresis > 100 mV
  • Connect up to 32 Nodes Plus Parallel Terminators on one Bus, or Connect
    up to 200 Nodes on an Unterminated Bus
  • Transient Protection
    • ±12 kV Human Body Model on Bus Pins
    • ±25 V Repetitive Transient Pulse on Bus Pins
  • Additional Reliability Features:
    • Bus Standoff From –35 V to 40 V
    • Driver Output Short-Circuit Current Limit
    • Automatic Thermal Shutdown and Recovery
  • Complies with ANSI/TIA-4963 Standard

  • Communicate Without Errors on Normal or Reversed-Wire Bus Lines
  • Up to 5 Mbps Signaling
  • Industrial Temperature Range: –40°C to 85°C
  • Symmetric Polarity Receiver
  • Receiver Hysteresis > 100 mV
  • Connect up to 32 Nodes Plus Parallel Terminators on one Bus, or Connect
    up to 200 Nodes on an Unterminated Bus
  • Transient Protection
    • ±12 kV Human Body Model on Bus Pins
    • ±25 V Repetitive Transient Pulse on Bus Pins
  • Additional Reliability Features:
    • Bus Standoff From –35 V to 40 V
    • Driver Output Short-Circuit Current Limit
    • Automatic Thermal Shutdown and Recovery
  • Complies with ANSI/TIA-4963 Standard

The SN65HVD96 is specifically designed to meet the requirements for a transceiver which operates with no errors if the twisted-pair signal wires are connected normally or reversed. This allows for error free operation in applications where the signal wires may become inadvertently reversed during installation or maintenance. This feature is corrected internally so no intervention from the controller or operator is required. The SN65HVD96 complies with the requirements of ANSI/TIA-4963, Electrical Characteristics of Reversible Balanced Voltage Digital Interface Circuits.

Similar to RS-485, these transceivers can be used for point-to-point, multi-drop, or multi-point networks. Sympol devices are not backwards compatible with, but are an upgrade to, existing RS-485 networks. The pin-out is identical to the industry-standard SN75176 transceiver, allowing direct upgrade from RS-485 to SymPol. Current-limited differential outputs protect in case of driver contention on a party-line bus. High receiver input impedance allows connection of at least 32 nodes. Several fault tolerant features are integrated into the device to protect from operational hazards. Current limiting on the driver outputs protects against short-circuit faults, and operates independently on each driver output. An automatic thermal shutdown protects the driver circuits against over temperature conditions. The receiver output enters a deterministic failsafe state if the bus connection is left disconnected or if the bus wires are shorted together.

The small outline integrated circuit (SOIC) package saves board space compared to equivalent discrete implementations. These devices are fully characterized for operation over the industrial temperature range of –40°C to 85°C.

The SN65HVD96 is specifically designed to meet the requirements for a transceiver which operates with no errors if the twisted-pair signal wires are connected normally or reversed. This allows for error free operation in applications where the signal wires may become inadvertently reversed during installation or maintenance. This feature is corrected internally so no intervention from the controller or operator is required. The SN65HVD96 complies with the requirements of ANSI/TIA-4963, Electrical Characteristics of Reversible Balanced Voltage Digital Interface Circuits.

Similar to RS-485, these transceivers can be used for point-to-point, multi-drop, or multi-point networks. Sympol devices are not backwards compatible with, but are an upgrade to, existing RS-485 networks. The pin-out is identical to the industry-standard SN75176 transceiver, allowing direct upgrade from RS-485 to SymPol. Current-limited differential outputs protect in case of driver contention on a party-line bus. High receiver input impedance allows connection of at least 32 nodes. Several fault tolerant features are integrated into the device to protect from operational hazards. Current limiting on the driver outputs protects against short-circuit faults, and operates independently on each driver output. An automatic thermal shutdown protects the driver circuits against over temperature conditions. The receiver output enters a deterministic failsafe state if the bus connection is left disconnected or if the bus wires are shorted together.

The small outline integrated circuit (SOIC) package saves board space compared to equivalent discrete implementations. These devices are fully characterized for operation over the industrial temperature range of –40°C to 85°C.

ダウンロード 字幕付きのビデオを表示 ビデオ

お客様が関心を持ちそうな類似品

open-in-new 代替品と比較
比較対象デバイスと類似の機能。
SN65HVD3082E アクティブ 半二重、RS-485 トランシーバ Equivalent RS485 Transceiver without cross wire immunity

技術資料

結果が見つかりませんでした。検索条件をクリアしてから、再度検索を試してください。
3 をすべて表示
上位の文書 タイプ タイトル フォーマットオプション 最新の英語版をダウンロード 日付
* データシート SymPol Transceiver. データシート (Rev. B) 2011/10/26
アプリケーション・ノート Using SN65HVD96 to Create a Power Over Data and Polarity Immunity Solution 2013/01/16
アプリケーション・ノート SymPol Transceivers are Immune to Cross-wire Faults 2010/10/26

設計と開発

その他のアイテムや必要なリソースを参照するには、以下のタイトルをクリックして詳細ページをご覧ください。

評価ボード

SN65HVD96EVM — SN65HVD96 向け評価モジュール

This EVM will allow a designer to evaluate the TI SymPol transceiver device. Multiple boards can be connected using the bus terminal blocks to simulate a simple bus system design.


ユーザー ガイド: PDF
サポート対象の製品とハードウェア
在庫あり
制限:
??asset.out-of-stock-ti_ja_JP??
入手不可
リファレンス・デザイン

TIDA-00862 — RS-485 2 線式全二重、リファレンス デザイン

このデザインでは、バス競合を利用することで、4 本ではなく 1 本の導体を使用して全二重 RS-485 通信を実現できます。電流を制限するために、バス ラインに値の小さいシリアル抵抗を追加すると、tri に記述された差動バスが許容され、SN65HVD96 SymPol トランシーバを使用してバス競合状態を検出できます。単純なデジタル ロジックとアナログ フィルタリング手法により、2 本の追加バス配線を必要とせずに、両方のトランシーバを互いに同時に駆動および受信できます。
サポート対象の製品とハードウェア
リファレンス・デザイン

TIDA-01171 — AC 結合 RS-485 リファレンス デザイン

TIDA-01171 リファレンス デザインを採用すると、非常に低いデータ レートでも、AC 結合リンク経由で RS-485 通信を実現できます。  これにより、ノード間で大きなグランド電位差が存在する場合でも、ノードは通信できます。  また、AC 結合を使用すると、高電圧電源への直接短絡が発生する可能性のあるバス障害からトランシーバを保護するのにも役立ちます。
サポート対象の製品とハードウェア
パッケージ ピン数 CAD シンボル、フットプリント、および 3D モデル
SOIC (D) 8 Ultra Librarian

購入と品質

推奨製品には、この TI 製品に関連するパラメータ、評価基板、またはリファレンス デザインが存在する可能性があります。

サポートとトレーニング

TI E2E™ フォーラムでは、TI のエンジニアからの技術サポートを提供

コンテンツは、TI 投稿者やコミュニティ投稿者によって「現状のまま」提供されるもので、TI による仕様の追加を意図するものではありません。使用条件をご確認ください。

TI 製品の品質、パッケージ、ご注文に関するお問い合わせは、TI サポートをご覧ください。​​​​​​​​​​​​​​

ビデオ