제품 상세 정보

Device type Current sensing Peak-to-peak input voltage range (V) 50mV Interface type Serial CMOS Sample rate (max) (Msps) 21 Rating Catalog CMTI (min) (kV/µs) 75 Number of input channels 1 Architecture Delta-Sigma SNR (dB) 77 Operating temperature range (°C) -40 to 125 Power consumption (typ) (mW) 85.8 SFDR (dB) 87 Isolation rating Reinforced Withstand isolation voltage (VISO) (Vrms) 4250 Working isolation voltage (VIOWM) (Vrms) 1200 Transient isolation voltage (VIOTM) (VPK) 6 Creepage (min) (mm) 8 Clearance (min) (mm) 8
Device type Current sensing Peak-to-peak input voltage range (V) 50mV Interface type Serial CMOS Sample rate (max) (Msps) 21 Rating Catalog CMTI (min) (kV/µs) 75 Number of input channels 1 Architecture Delta-Sigma SNR (dB) 77 Operating temperature range (°C) -40 to 125 Power consumption (typ) (mW) 85.8 SFDR (dB) 87 Isolation rating Reinforced Withstand isolation voltage (VISO) (Vrms) 4250 Working isolation voltage (VIOWM) (Vrms) 1200 Transient isolation voltage (VIOTM) (VPK) 6 Creepage (min) (mm) 8 Clearance (min) (mm) 8
SO-MOD (DWE) 16 106.09 mm² 10.3 x 10.3
  • 3.3-V or 5-V single supply with integrated DC/DC converter
  • ±50-mV input voltage range optimized for current measurement using shunt resistors
  • Low DC errors:
    • Offset error: ±50 µV (max)
    • Offset drift: ±0.4 µV/°C (max)
    • Gain error: ±0.2% (max)
    • Gain drift: ±35 ppm/°C (max)
  • High CMTI: 75 kV/µs (min)
  • System-level diagnostic features
  • Low EMI: meets CISPR-11 and CISPR-25 standards
  • Safety-related certifications:
    • 6000-VPEAK reinforced isolation per DIN VDE V 0884-11
    • 4250-VRMS isolation for 1 minute per UL1577
  • Fully specified over the extended industrial temperature range: –40°C to +125°C
  • 3.3-V or 5-V single supply with integrated DC/DC converter
  • ±50-mV input voltage range optimized for current measurement using shunt resistors
  • Low DC errors:
    • Offset error: ±50 µV (max)
    • Offset drift: ±0.4 µV/°C (max)
    • Gain error: ±0.2% (max)
    • Gain drift: ±35 ppm/°C (max)
  • High CMTI: 75 kV/µs (min)
  • System-level diagnostic features
  • Low EMI: meets CISPR-11 and CISPR-25 standards
  • Safety-related certifications:
    • 6000-VPEAK reinforced isolation per DIN VDE V 0884-11
    • 4250-VRMS isolation for 1 minute per UL1577
  • Fully specified over the extended industrial temperature range: –40°C to +125°C

The AMC3306M05 is a precision, isolated delta-sigma (ΔΣ) modulator, optimized for shunt-based current measurements. The fully integrated, isolated DC/DC converter allows single-supply operation from the low-side of the device which makes the device a unique solution for space-constrained applications. The reinforced capacitive isolation barrier is certified according to VDE V 0884-11 and UL1577 and supports a working voltage of up to 1.2 kVRMS.

The isolation barrier separates parts of the system that operate on different common-mode voltage levels and protects the low-voltage side from hazardous voltages and damage.

The input of the AMC3306M05 is optimized for direct connection to a low-impedance shunt resistor or other, low-impedance voltage source with low signal levels. The excellent DC accuracy and low temperature drift supports accurate current measurments over the extended industial temperature range from –40°C to +125°C.

By using a digital filter (such as a sinc3 filter) to decimate the bitstream, the device can achieve 16 bits of resolution with a dynamic range of 85 dB at a data rate of 78 kSPS.

The AMC3306M05 is a precision, isolated delta-sigma (ΔΣ) modulator, optimized for shunt-based current measurements. The fully integrated, isolated DC/DC converter allows single-supply operation from the low-side of the device which makes the device a unique solution for space-constrained applications. The reinforced capacitive isolation barrier is certified according to VDE V 0884-11 and UL1577 and supports a working voltage of up to 1.2 kVRMS.

The isolation barrier separates parts of the system that operate on different common-mode voltage levels and protects the low-voltage side from hazardous voltages and damage.

The input of the AMC3306M05 is optimized for direct connection to a low-impedance shunt resistor or other, low-impedance voltage source with low signal levels. The excellent DC accuracy and low temperature drift supports accurate current measurments over the extended industial temperature range from –40°C to +125°C.

By using a digital filter (such as a sinc3 filter) to decimate the bitstream, the device can achieve 16 bits of resolution with a dynamic range of 85 dB at a data rate of 78 kSPS.

다운로드 스크립트와 함께 비디오 보기 비디오

기술 자료

설계 및 개발

추가 조건 또는 필수 리소스는 사용 가능한 경우 아래 제목을 클릭하여 세부 정보 페이지를 확인하세요.

평가 보드

AMC-MOD-50A-EVM — 50A 절연 전류 감지를 위한 AMC1306 평가 모듈

AMC-MOD-50A-EVM은 ±50A 션트 기반 전류 감지를 위해 설계된 절연 전류 감지 평가 모듈입니다. 이 EVM을 사용하면 외부 션트 저항을 통해 최대 ±50A 피크 전류를 감지하는 동시에 AMC1306M05의 절연 장벽을 통해 절연 출력을 측정할 수 있습니다. AMC1306M05는 션트 기반 전류 측정에 최적화된 고정밀 절연 모듈레이터이며 Isabellenhütte™ BVN-M-R001 션트 저항과 함께 사용할 수 있습니다. 이 EVM은 비아 스티칭은 큰 전류에서 방열을 용이하게 하며 ±1%(일반) 이내의 정확도로 (...)

사용 설명서: PDF | HTML
TI.com에서 구매할 수 없음
평가 보드

AMC3306EVM — AMC3306 정밀 강화 절연 모듈레이터와 통합 DC/DC 컨버터 평가 모듈

AMC3306 평가 모듈(EVM)은 증폭기의 고압측에 전원을 공급하는 통합 DC/DC 컨버터를 갖춘 정밀 절연 증폭기인 AMC3306 제품을 평가하기 위한 플랫폼입니다. AMC3306은 전류 션트 측정 애플리케이션에 사용하도록 설계된 7kV 강화 절연 모듈레이터입니다.

회로도 다이어그램 및 BOM(재료 사양서)는 물론 완전한 회로 설명이 사용 설명서에 포함되어 있습니다.

사용 설명서: PDF | HTML
TI.com에서 구매할 수 없음
계산 툴

MODULATOR-TIMING-EXCEL-CALC Isolated Modulator Digital Communication Timing Calculation Tool

Use this excel calculator to confirm the correct clock setup and hold timing compensation method with an isolated modulator and SDFM controller.
지원되는 제품 및 하드웨어

지원되는 제품 및 하드웨어

계산 툴

SBAR010 Delta Sigma Modulator Filter Calculator

지원되는 제품 및 하드웨어

지원되는 제품 및 하드웨어

계산 툴

SBAR013 Isolated Amplifier Voltage Sensing Excel Calculator

This calculator provides estimates of the errors associated with using isolation amplifier devices in a voltage sensing configuration.
지원되는 제품 및 하드웨어

지원되는 제품 및 하드웨어

계산 툴

SBAR020 Isolated Amplifier Current Sensing Excel Calculator

This calculator provides estimates of the errors associated with using isolation amplifier devices in a current sensing configuration.
지원되는 제품 및 하드웨어

지원되는 제품 및 하드웨어

레퍼런스 디자인

PMP23630 — HVDC 30kW PSU용 데이터센터 레퍼런스 설계

이 레퍼런스 설계는 HVDC(고전압 DC) 출력을 지원하는 2단계의 고효율 30kW 전원 공급 장치입니다. 첫 번째 단계는 3상 입력 소스에서 실행되는 3레벨 플라잉 커패시터 PFC(역률 보정) 컨버터입니다. PFC 제어는 TMS320F28P650DK 고성능 마이크로컨트롤러로 구현됩니다. 플라잉 커패시터 토폴로지는 인덕터의 주파수 배가 효과로 인해 이전 토폴로지(예: Vienna 정류기) 대신 선택되었습니다. 이러한 배가 효과를 통해 인덕터가 더 작아지고 효율이 더 높아집니다. PFC 다음 단계는 2개의 Δ-Δ 연결 3상 (...)
Test report: PDF
레퍼런스 디자인

TIDA-01606 — 11kW, 양방향 3상 3레벨(T형) 인버터 및 PFC 레퍼런스 설계

이 레퍼런스 설계는 양방향 3레벨, 3상, SiC 기반 AFE(액티브 프론트 엔드) 인버터 및 PFC(역률 보정) 단계를 구현하는 방법을 보여줍니다. 이 설계에서는 최대 90KHz의 스위칭 주파수와 LCL 출력 필터를 사용하여 자기 크기를 줄입니다. 98.6%의 피크 효율이 달성됩니다. 이 설계는 DQ 영역에서 완전한 3상 AFE 제어를 구현하는 방법을 보여줍니다. 이 양방향 컨버터는 DC 급속 충전 및 V2G(Vehicle-to-Grid) 애플리케이션을 모두 지원합니다.
Design guide: PDF
회로도: PDF
패키지 CAD 기호, 풋프린트 및 3D 모델
SO-MOD (DWE) 16 Ultra Librarian

주문 및 품질

포함된 정보:
  • RoHS
  • REACH
  • 디바이스 마킹
  • 납 마감/볼 재질
  • MSL 등급/피크 리플로우
  • MTBF/FIT 예측
  • 물질 성분
  • 인증 요약
  • 지속적인 신뢰성 모니터링
포함된 정보:
  • 팹 위치
  • 조립 위치

권장 제품에는 본 TI 제품과 관련된 매개 변수, 평가 모듈 또는 레퍼런스 디자인이 있을 수 있습니다.

지원 및 교육

TI 엔지니어의 기술 지원을 받을 수 있는 TI E2E™ 포럼

콘텐츠는 TI 및 커뮤니티 기고자에 의해 "있는 그대로" 제공되며 TI의 사양으로 간주되지 않습니다. 사용 약관을 참조하십시오.

품질, 패키징, TI에서 주문하는 데 대한 질문이 있다면 TI 지원을 방문하세요. ​​​​​​​​​​​​​​

동영상