TVS1801
- Protection against 1 kV, 42-Ω IEC 61000-4-5 surge test for industrial signal lines
- Bidirectional polarity enables protection against bipolar signaling or miswiring conditions
- Clamping voltage of 27.4 V at 30 A of 8/20 µs surge current
- Standoff voltage: ±18 V
- Small 3 mm × 3 mm SON footprint
- Survives over 5,000 repetitive strikes of 30-A 8/20 µs surge current at 125°C
- Robust surge protection
- IEC61000-4-5 (8/20 µs): 30 A
- IEC61643-321 (10/1000 µs): 4.5 A
- Low leakage current
- 0.4 nA typical at 27°C
- 280 nA maximum at 85°C
- Low capacitance: 65 pF
- Integrated level 4 IEC 61000-4-2 ESD protection
The TVS1801 device shunts up to 30 A of IEC 61000-4-5 fault current to protect systems from high-power transients or lightning strikes. The device survives the common industrial signal line EMC requirement of 1-kV IEC 61000-4-5 open circuit voltage coupled through a 42-Ω impedance. The TVS1801 uses a feedback mechanism to ensure precise flat clamping during a fault, keeping system exposure lower than traditional TVS diodes. The tight voltage regulation allows designers to confidently select system components with a lower voltage tolerance, lowering system costs and complexity without sacrificing robustness. The TVS1801 has a ±18-V operating range to enable operation in systems that require protection against reverse wiring conditions.
In addition, the TVS1801 is available in a small SON footprint designed for space constrained applications, offering a significant size reduction compared to standard SMA and SMB packages. Low device leakage and capacitance ensure a minimal effect on the protected line. To ensure robust protection over the lifetime of the product, TI tests the TVS1801 against 5000 repetitive surge strikes at 125°C with no shift in device performance.
The TVS1801 is part of TIs Flat-Clamp family of surge devices. For a deeper look at the Flat-Clamp family, refer to the Flat-Clamp Surge Protection Technology for Efficient System Protection white paper.
기술 자료
| 상위 문서 | 유형 | 직함 | 형식 옵션 | 최신 영어 버전 다운로드 | 날짜 |
|---|---|---|---|---|---|
| * | 데이터 시트 | TVS1801 18-V Bidirectional Flat-Clamp Surge Protection Device datasheet (Rev. B) | PDF | HTML | 2022. 3. 5 | |
| Application brief | Protecting I/O modules from surge events | 2019. 2. 4 | |||
| Application brief | TVS Surge Rating: Power vs. Current | 2018. 11. 12 | |||
| 백서 | Demystifying surge protection | 2018. 11. 6 | |||
| 사용 설명서 | Flat Clamp TVS Evaluation Module—Adaptor Boards | 2018. 9. 10 | |||
| 애플리케이션 노트 | How to select a Surge Diode | 2018. 8. 29 |
설계 및 개발
추가 조건 또는 필수 리소스는 사용 가능한 경우 아래 제목을 클릭하여 세부 정보 페이지를 확인하세요.
FLAT-CLAMP-TVS-EVM — TVSxx0x 정밀 서지 보호 다이오드 평가 모듈
TIDA-010008 — 그리드 애플리케이션의 과도 차단 기능을 위한 평면 클램프 TV 기반 레퍼런스 설계
TIDA-010089 — 2사분면, 15V, 8A, 프로그래머블 선형 DC 전원 공급 장치 레퍼런스 설계
이 레퍼런스 설계는 잡음이 적고 효율적인 양방향 전원 공급 장치를 나타낸 것으로, FS(최대 눈금) 전류 및 전압 제어 정확도가 ±0.02% 미만입니다. 이 설계는 아날로그 피드백 루프를 활용해 전류를 정밀하게 제어하고, 전압 추적 회로를 구현하여 소스 모드의 선형 단계에서 전력 손실을 최소화합니다. 이 구현의 경우 120W 출력 전력을 지원하고, 외부 냉각을 활용해 최대 25W까지 싱크할 수 있습니다.
| 패키지 | 핀 | CAD 기호, 풋프린트 및 3D 모델 |
|---|---|---|
| VSON (DRB) | 8 | Ultra Librarian |
주문 및 품질
권장 제품에는 본 TI 제품과 관련된 매개 변수, 평가 모듈 또는 레퍼런스 디자인이 있을 수 있습니다.