產品詳細資料

Device type Current sensing Output type Differential Peak-to-peak input voltage range (V) 0.05 Isolation rating Reinforced Withstand isolation voltage (VISO) (Vrms) 4250 Working isolation voltage (VIOWM) (Vrms) 1200 Transient isolation voltage (VIOTM) (VPK) 6000 CMTI (min) (kV/µs) 85 Creepage (min) (mm) 8 Clearance (min) (mm) 8 Input offset (±) (max) (V) 0.0001 Input offset drift (±) (typ) (µV/°C) 0.15 Rating Automotive Operating temperature range (°C) -40 to 125
Device type Current sensing Output type Differential Peak-to-peak input voltage range (V) 0.05 Isolation rating Reinforced Withstand isolation voltage (VISO) (Vrms) 4250 Working isolation voltage (VIOWM) (Vrms) 1200 Transient isolation voltage (VIOTM) (VPK) 6000 CMTI (min) (kV/µs) 85 Creepage (min) (mm) 8 Clearance (min) (mm) 8 Input offset (±) (max) (V) 0.0001 Input offset drift (±) (typ) (µV/°C) 0.15 Rating Automotive Operating temperature range (°C) -40 to 125
SO-MOD (DWE) 16 106.09 mm² (10.3 mm × 10.3 mm)
  • AEC-Q100 qualified for automotive applications:
    • Temperature grade 1: –40°C to +125°C, TA
  • 3.3-V or 5-V single supply with integrated DC/DC converter
  • ±50-mV input voltage range optimized for current measurement using shunt resistors
  • Fixed gain: 41
  • Low DC errors:
    • Offset voltage: ±50 µV (maximum)
    • Offset drift: ±0.5 µV/°C (maximum)
    • Gain error: ±0.2% (maximum)
    • Gain error drift: ±35 ppm/°C (maximum)
    • Nonlinearity: ±0.03% (maximum)
  • High CMTI: 95 kV/µs (minimum)
  • System-level diagnostic features
  • Meets CISPR-11 and CISPR-25 EMI standards
  • Safety-related certifications:
    • 6000-VPK reinforced isolation per DIN VDE V 0884-11
    • 4250-VRMS isolation for 1 minute per UL1577
  • AEC-Q100 qualified for automotive applications:
    • Temperature grade 1: –40°C to +125°C, TA
  • 3.3-V or 5-V single supply with integrated DC/DC converter
  • ±50-mV input voltage range optimized for current measurement using shunt resistors
  • Fixed gain: 41
  • Low DC errors:
    • Offset voltage: ±50 µV (maximum)
    • Offset drift: ±0.5 µV/°C (maximum)
    • Gain error: ±0.2% (maximum)
    • Gain error drift: ±35 ppm/°C (maximum)
    • Nonlinearity: ±0.03% (maximum)
  • High CMTI: 95 kV/µs (minimum)
  • System-level diagnostic features
  • Meets CISPR-11 and CISPR-25 EMI standards
  • Safety-related certifications:
    • 6000-VPK reinforced isolation per DIN VDE V 0884-11
    • 4250-VRMS isolation for 1 minute per UL1577

The AMC3302-Q1 is a precision, isolated amplifier optimized for shunt-based current measurements. The fully integrated, isolated DC/DC converter allows single-supply operation from the low-side of the device, which makes the device a unique solution for space-constrained applications. The reinforced capacitive isolation barrier is certified according to VDE V 0884-11 and UL1577 and supports a working voltage of up to 1.2 kVRMS.

The isolation barrier separates parts of the system that operate on different common-mode voltage levels and protects the low-voltage side from hazardous voltages and damage.

The input of the AMC3302-Q1 is optimized for direct connection to a low-impedance shunt resistor or another low-impedance voltage source with low signal levels. The excellent DC accuracy and low temperature drift supports accurate current measurements in the temperature range from –40°C to +125°C.

The integrated DC/DC converter fault-detection and diagnostic output pin of the AMC3302-Q1 simplify system-level design and diagnostics.

The AMC3302-Q1 is a precision, isolated amplifier optimized for shunt-based current measurements. The fully integrated, isolated DC/DC converter allows single-supply operation from the low-side of the device, which makes the device a unique solution for space-constrained applications. The reinforced capacitive isolation barrier is certified according to VDE V 0884-11 and UL1577 and supports a working voltage of up to 1.2 kVRMS.

The isolation barrier separates parts of the system that operate on different common-mode voltage levels and protects the low-voltage side from hazardous voltages and damage.

The input of the AMC3302-Q1 is optimized for direct connection to a low-impedance shunt resistor or another low-impedance voltage source with low signal levels. The excellent DC accuracy and low temperature drift supports accurate current measurements in the temperature range from –40°C to +125°C.

The integrated DC/DC converter fault-detection and diagnostic output pin of the AMC3302-Q1 simplify system-level design and diagnostics.

下載 觀看有字幕稿的影片 影片

技術文件

找不到結果。請清除您的搜尋條件,然後再試一次。
檢視所有 15
重要文件 類型 標題 格式選項 下載最新的英文版本 日期
* 資料表 AMC3302-Q1 Automotive High-Precision, ±50-mV Input, Reinforced Isolated Amplifier With Integrated DC/DC Converter datasheet (Rev. A) PDF | HTML 2021/7/7
證書 VDE Certificate for Reinforced Isolation for DIN EN IEC 60747-17 (Rev. AB) 2026/7/15
Application brief Optimized Excitation Power Stage for Electrically Excited Synchronous Machines (Rev. A) PDF | HTML 2026/5/5
應用說明 AMC High Side Power Supply Options PDF | HTML 2025/10/15
應用說明 Isolated Converters CISPR25 Radiated Emissions PDF | HTML 2025/10/13
白皮書 Comparing Isolated Amplifiers and Isolated Modulators (Rev. B) PDF | HTML 2024/6/4
Application brief Utilizing AMC3311 to Power AMC23C11 for Isolated Sensing and Fault Detection PDF | HTML 2023/11/9
Application brief Interfacing a Differential-Output (Isolated) Amp to a Single-Ended Input ADC (Rev. B) PDF | HTML 2023/6/2
Application brief Shunt Resistor Selection for Isolated Data Converters PDF | HTML 2023/5/4
Circuit design Isolated Current-Sensing Circuit With Front-End Gain Stage PDF | HTML 2023/4/24
Application brief Comparing shunt- and hall-based isolated current-sensing solutions in HEV/EV (Rev. C) PDF | HTML 2023/3/28
證書 UL Certificate of Compliance Vol4 Sec5 E181974 (Rev. A) 2023/1/23
應用說明 Best Practices to Attenuate AMC3301 Family Radiated Emissions EMI (Rev. A) PDF | HTML 2022/9/22
Circuit design Isolated Current-Sensing Circuit With ±50-mV Input and Single-Ended Output PDF | HTML 2022/7/28
Circuit design Isolated Current-Sensing Circuit With ±50-mV Input and Differential Output PDF | HTML 2022/6/30

設計與開發

如需其他條款或必要資源,請按一下下方的任何標題以檢視詳細頁面 (如有)。

開發板

AMC-AMP-50A-EVM — 適用於 ±50A AMCxx 放大器的評估模組

AMC-AMP-50A-EVM 是一款隔離式電流感測評估模組 (EVM),專為 ±50A 分流架構電流感測設計。此 EVM 可讓使用者透過外部分流電阻器感測高達 ±50A 峰值電流,同時透過 AMC3302 的隔離層測量隔離輸出。AMC3302 是一款針對分流架構電流量測最佳化的精密隔離式放大器,並與 Isabellenhütte BVN-BVN- M R001 分流電阻器配對。此 EVM 透過拼接提供在大電流下促進散熱,並可在 ±1% (典型) 準確度內運作。
使用指南: PDF | HTML
支援產品和硬體
有庫存
限制:
??asset.out-of-stock-ti_zh_TW??
無法提供
開發板

AMC3302EVM — 適用於 ±50-mV 輸入精密強化型隔離放大器的 AMC3302 評估模組

AMC3302 評估模組 (EVM) 是用於評估 AMC3302 的平台,此平台是具備整合式 DC/DC 轉換器的精密隔離式放大器,可供電給放大器高壓側。AMC3302 是一款 7-kV 強化型隔離式放大器,主要設計用於電流分流測量應用。

使用指南中包含完整的電路描述、電路圖和物料清單 (BOM)。

使用指南: PDF | HTML
支援產品和硬體
有庫存
限制:
??asset.out-of-stock-ti_zh_TW??
無法提供
模擬型號

AMC3302 TINA-TI Spice Model (Rev. B)

SBAM444B (152 KB) - TINA-TI Spice 模型
支援產品和硬體
計算工具

SBAR013 — Isolated Amplifier Voltage Sensing Excel Calculator

This calculator provides estimates of the errors associated with using isolation amplifier devices in a voltage sensing configuration.
支援產品和硬體
計算工具

SBAR020 — Isolated Amplifier Current Sensing Excel Calculator

This calculator provides estimates of the errors associated with using isolation amplifier devices in a current sensing configuration.
支援產品和硬體
封裝 針腳 CAD 符號、佔位空間與 3D 模型
SO-MOD (DWE) 16 Ultra Librarian

訂購與品質

建議產品可能具有與此 TI 產品相關的參數、評估模組或參考設計。

支援與培訓

內含 TI 工程師技術支援的 TI E2E™ 論壇

內容係由 TI 和社群貢獻者依「現狀」提供,且不構成 TI 規範。檢視使用條款

若有關於品質、封裝或訂購 TI 產品的問題,請參閱 TI 支援。​​​​​​​​​​​​​​