The GVDD charge pump/LDO provides a regulated
voltage of approximately 12V on the GVDD pin. GVDD is a power supply source of the
bootstrap diode and also the VCP trickle charge pump.
Note: TI recommends setting
DIS_GVDD_SS to 1b after power up. In case DIS_GVDD_SS remains 0b, the GVDD output load capability
does not meet the test limits of electrical characteristic table when PVDD input
voltage is lower than 7.2V.