SLLS732A October 2006 – November 2019 SN65LBC174A-EP
PRODUCTION DATA.
Refer to the PDF data sheet for device specific package drawings
The drivers implemented in the RS-485 device can be configured using the EN logic pins set to enabled or disabled. This allows users to transmit or idle the bus as desired.
| INPUT
A |
ENABLE
G |
OUTPUTS | |
|---|---|---|---|
| Y | Z | ||
| L | H | L | H |
| H | H | H | L |
| OPEN | H | H | L |
| L | OPEN | L | H |
| H | OPEN | H | L |
| OPEN | OPEN | H | L |
| X | L | Z | Z |