The VCC1 regulator output pin sources either 3.3V or 5V to with up to 250mA of load current. The VCC1 pin is capable of sinking a current, ICC1
SINK, depending upon the setting of register VCC1_SINK at 8'h0D[3] and is active when VCC1 is enabled. Refer to
Table 9-1 for the external capacitance requirement on this pin. There are three monitors on VCC1, under-voltage (UVCC1), over-voltage (OVCC1) and short to ground (VCC1
SC). When load sharing with VEXCC, VCC1 fault monitors are used for both. VCC1 is the main LDO output and sets the digital IO voltage levels. Any fault on VCC1 causes a state change.