TCAN285x-Q1
monitors VCC1, VEXCC and VCC2 for over-voltage condition. Over-voltage is represented by
OVCC1, OVCC2 and OVEXCC. When OVCC1 occurs, the device enters either fail-safe mode, if
enabled, or sleep mode. When OVCC2 or OVEXCC takes place, the LDOs are turned off and an
interrupt flag is set but no mode change takes place. When entering fail-safe mode, the
device turns off all the LDOs and starts the t
LDOOFF timer. After this timer
times out, OVCC1 is checked for over-voltage. If the OV event has cleared, and a wake
event has taken place, the device enters restart mode. If OVCC1 is still present, the
device enters sleep mode. Wake events are monitored but not acted upon until
t
LDOOFF time out. If no wake event has taken place and the OV event has
cleared. the device is still in fail-safe mode until the SWE timer times out or a wake
event takes place. See
Figure 8-51,
Figure 8-52 and
Figure 8-53 for
device behavior during an over-voltage event.
Note: When VCC1_CFG = 01b for VCC1
always on, or FSM CNTR exceeded, a wake event is not needed to exit the fail-safe
mode. The device exits the fail-safe mode after tLDOOFF timer
expires.