SLUSFM0 May 2025 TPS4816-Q1
PRODUCTION DATA
In the applications where low power bypass path is not used, the cap charging can be done using main FET GATE drive control.
For limiting inrush current during turn-ON of the main FET with capacitive loads, use R1, R2, C1, D2 as shown in Figure 8-4. The R1 and C1 components slow down the voltage ramp rate at the gate of main FET. The FET source follows the gate voltage resulting in a controlled voltage ramp across the output capacitors.
Use a damping resistor R2 (~ 10 Ω) in series with C1. D2 ensures fast turn OFF of GATE drive by bypassing R1.