SLUSFM0 May 2025 TPS4816-Q1
PRODUCTION DATA
The TPS4816-Q1 devices features integrated reverse polarity protection to protect the device from failing during input and output reverse polarity faults. Reverse polarity faults occur during installation and maintenance of the end equipment’s. The device is tolerant to reverse polarity voltages down to –65 V both on input and on the output.
TPS4816-Q1 uses DRN pin for sensing input reverse polarity fault event. If DRN pin voltage goes below V(REV_DRN) = 1.5V (irrespective of VS voltage) then gate drive is turned off.
On the output side, the device can see transient negative voltages during regular operation due to output cable harness inductance kickbacks when the switches are turned OFF. In such systems the output negative voltage level is limited by the output side TVS or a diode