SLUSG51A October 2025 – August 2026 BQ25692-Q1
PRODUCTION DATA
In some applications, such as batteries with high-leakage or batteries in parallel with a system load, the battery current does not always reach the ITERM threshold while in CV mode. The device offers a dedicated CV timer to control the amount of time the charger stays in CV mode.
The CV timer begins counting when the device enters the CV mode, and the timer duration can be programmed through the CV_TMR register bits. Note that CV_TMR = 0 disables the timer altogether. The CV timer is an absolute timer, and the EN_TMR2X register bit has no effect on the timer.
During faults which disable charging or when device falls out of CV regulation due to IAC_DPM or VAC_DPM, the CV timer is suspended. Once the device return to CV mode, the CV timer resumes. If the charging cycle is stopped and started again, the timer resets (toggle CE pin or EN_CHG bit restarts the timer).
An INT is asserted to the host when CV timer expires. Mask the INT using the CV_TMR_MASK bit.