SLUSG59 February 2026 BQ27Z855
ADVANCE INFORMATION
Once the battery voltage reaches the charge voltage regulation target (VBAT_REG), the device operates in Taper-charge mode. The CV loop becomes dominant and the charging current begins to naturally taper off. The different VBAT_REG settings the CV loop can regulate charging voltage at based on the present temperature range is configurable within device data flash (Refer to the Charging Voltage section of the BQ27Z855 Technical Reference Manual). Once the charging current reaches the termiantion current target (ITERM) programmed by the Charge Term Taper Current data flash parameter and all Valid Charge Termination conditions stated in the BQ27Z855 Technical Reference Manual are met, battery charging is done and the device sets the [VCT] bit.