SLVSI75 May 2026 DRV8218
ADVANCE INFORMATION
An analog current limit circuit on each MOSFET limits the peak current out of the device even in hard short circuit events. If the output current exceeds the overcurrent threshold, IOCP, for longer than the overcurrent deglitch time, tOCP, all MOSFETs in the H-bridge are disabled. After tRETRY, the MOSFETs are re-enabled according to the state of the PH/IN1 and EN/IN2 pins. If the overcurrent condition is still present, the cycle repeats; otherwise normal device operation resumes.
In half-bridge control mode, the OCP behavior is slightly modified. If an overcurrent event is detected, only the corresponding half-bridge is disabled. The other half-bridge continues normal operation. This allows for the device to manage independent fault events when driving independent loads. If an overcurrent event is detected in both half-bridges, both half-bridges are disabled. Both half-bridges share the same overcurrent retry timer. If an overcurrent event occurs first in OUT1, that output is disabled for the duration of tRETRY. If OUT2 experiences an overcurrent event after OUT1, but before tRETRY has expired, then both OUTx pins remain disabled for a full duration of tRETRY.