SLVSIA7
March 2025
TPSI3050M
PRODUCTION DATA
1
1
Features
2
Applications
3
Description
4
Pin Configuration and Functions
5
Specifications
5.1
Absolute Maximum Ratings
5.2
ESD Ratings
5.3
Recommended Operating Conditions
5.4
Thermal Information
5.5
Power Ratings
5.6
Insulation Specifications
5.7
Safety-Related Certifications
5.8
Safety Limiting Values
5.9
Electrical Characteristics
5.10
Switching Characteristics
5.11
Insulation Characteristic Curves
5.12
Typical Characteristics
6
Parameter Measurement Information
7
Detailed Description
7.1
Overview
7.2
Functional Block Diagram
7.3
Feature Description
7.3.1
Transmission of the Enable State
7.3.2
Power Transmission
7.3.3
Gate Driver
7.3.4
Modes Overview
7.3.5
Three-Wire Mode
7.3.6
Two-Wire Mode
7.3.7
VDDP, VDDH, and VDDM Undervoltage Lockout (UVLO)
7.3.8
Keep-Off Circuitry
7.3.9
Power Supply and EN Sequencing
7.3.10
Thermal Shutdown
7.4
Device Functional Modes
8
Application and Implementation
8.1
Application Information
8.2
Typical Application
8.2.1
Design Requirements
8.2.2
Detailed Design Procedure
8.2.2.1
Two-Wire or Three-Wire Mode Selection
8.2.2.2
CDIV1, CDIV2 Capacitance
8.2.2.3
RPXFR Selection
8.2.2.4
CVDDP Capacitance
8.2.2.5
Gate Driver Output Resistor
8.2.2.6
Start-up Time and Recovery Time
8.2.2.7
Supplying Auxiliary Current, IAUX From VDDM
8.2.2.8
VDDM Ripple Voltage
8.2.3
Application Curves
8.2.4
Insulation Lifetime
8.3
Power Supply Recommendations
8.4
Layout
8.4.1
Layout Guidelines
8.4.2
Layout Example
9
Device and Documentation Support
9.1
Receiving Notification of Documentation Updates
9.2
Support Resources
9.3
Trademarks
9.4
Electrostatic Discharge Caution
9.5
Glossary
10
Revision History
11
Mechanical, Packaging, and Orderable Information
1
Features
No isolated secondary supply required
Drives external power transistors or SCRs
5kV
RMS
reinforced isolation
10V
gate drive; 1.5A/2.5A peak source/sink current
Up to 50mW supply for external auxiliary circuitry
Supports AC or DC switching
Supports two-wire or three-wire modes
Seven levels of power transfer, resistor selectable
Functional Safety-Capable
Documentation available to aid functional safety system design
Temperature range –55°C to 125°C ambient
Safety-related certifications
Planned: 7071V
PK
reinforced isolation per DIN EN IEC 60747-17 (VDE 0884-17)
Planned: 5kV
RMS
isolation for 1 minute per UL 1577